ALTERNATIVE MERCURY PALLADIUM CHEMICAL MODIFIER FOR THE DETERMINATION OF SELENIUM IN COAL FLY-ASH BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY

被引:15
作者
GARCIAOLALLA, C
ALLER, AJ
机构
[1] Department of Biochemistry and Molecular Biology, University of León
关键词
ATOMIC ABSORPTION SPECTROMETRY; COAL FLY ASH; SELENIUM;
D O I
10.1016/0003-2670(92)85379-K
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An alternative chemical modifier containing HgCl2-PdCl2 was used to develop an accurate method for the determination of selenium in coal fly ash. Wall atomization and the Smith-Hieftie background correction method were used. The determination was done either by the standard additions method or by using a calibration graph obtained for selenium in matrix-free solutions with the modifier. A detection limit of 7.45-mu-g l-1 and an optimum concentration range of up to 120-mu-g l-1 were obtained.
引用
收藏
页码:295 / 303
页数:9
相关论文
共 30 条
[1]   EFFECTS OF SELECTED TRACE-ELEMENTS ON PLANT-GROWTH [J].
ALLER, AJ ;
BERNAL, JL ;
DELNOZAL, MJ ;
DEBAN, L .
JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1990, 51 (04) :447-479
[2]  
ALLER AJ, UNPUB J ANAL AT SPEC
[3]   DETERMINATION OF ARSENIC, CADMIUM, LEAD, ANTIMONY, SELENIUM AND THALLIUM IN COAL FLY-ASH USING THE STABILIZED TEMPERATURE PLATFORM FURNACE AND ZEEMAN-EFFECT BACKGROUND CORRECTION [J].
BETTINELLI, M ;
BARONI, U ;
PASTORELLI, N .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (07) :1005-1011
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATOMIC-ABSORPTION SPECTROMETRY INTERFACE FOR THE DETERMINATION OF SELENONIOCHOLINE AND TRIMETHYLSELENONIUM CATIONS - APPLICATION TO HUMAN URINE [J].
BLAIS, JS ;
HUYGHUESDESPOINTES, A ;
MOMPLAISIR, GM ;
MARSHALL, WD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (03) :225-232
[5]   DETERMINATION OF SELENIUM IN BIOLOGICAL-MATERIALS WITH PLATFORM FURNACE ATOMIC-ABSORPTION SPECTROSCOPY AND ZEEMAN BACKGROUND CORRECTION [J].
CARNRICK, GR ;
MANNING, DC ;
SLAVIN, W .
ANALYST, 1983, 108 (1292) :1297-1312
[6]   MATRIX INTERFERENCES IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY BY CAPACITIVE DISCHARGE HEATING [J].
CHAKRABARTI, CL ;
WAN, CC ;
HAMED, HA ;
BERTELS, PC .
ANALYTICAL CHEMISTRY, 1981, 53 (03) :444-450
[7]   DEALING WITH INTERFERENCES IN FURNACE ATOMIZER AAS - SE IN NICKEL-ALLOYS [J].
DULUDE, GR ;
SOTERA, JJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (2-3) :511-518
[8]  
DULUDE GR, 1989, SPECTROSC INTER, V1, P44
[9]  
FERNANDEZ FJ, 1982, ATOM SPECTROSC, V3, P61
[10]   THE EFFECT OF METAL CHLORIDES, SULFATES AND NITRATES ON ATOMIZATION OF SELENIUM IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
GARCIAOLALLA, C ;
ROBLES, LC ;
ALLER, AJ .
ANALYTICAL SCIENCES, 1991, 7 (04) :611-615