A new procedure for obtaining analytical kinetic Information in single-line flow infection analysis (FIA) system is described. A microcomputer-controlled FIA system Is first used to acquire and store the peak profiles of a nonreactlng reference solution and a reacting sample solution. Next the sample FIA response is normalized in the time domain by multiplying the signal response by the relative sample dispersion coefficients calculated from the reference profile. in the absence of a chemical reaction, the normalized sample profile is flat. When the slow chemical reaction is in progress during the time between injection and detection, the signal varies across the normalized profile and analytical kinetic information can be extracted under certain conditions. Chemical and instrumental variables were optimized for a fluorometric kinetic determination of Al3+ with the fixed-time method. A 13 ng/mL detection limit was achieved. The proposed method Is shown to discriminate against the Interference from riboflavin, a nonreactlng fluorescent species. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:2547 / 2552
页数:6
相关论文
共 12 条
[1]   FLUORIMETRIC REACTION-RATE METHOD FOR THE DETERMINATION OF ALUMINUM WITH ACID ALIZARIN GARNET-R [J].
CAMPI, GL ;
INGLE, JD .
ANALYTICA CHIMICA ACTA, 1989, 224 (02) :363-372
[2]   DETECTION AND CORRECTION OF MULTIPLICATIVE INTERFERENCES IN SINGLE-LINE FLOW-INJECTION ANALYSIS WITH FLUORESCENCE DETECTION [J].
CHUNG, HK ;
INGLE, JD .
ANALYTICAL CHEMISTRY, 1990, 62 (23) :2541-2547
[3]   FLOW-INJECTION SYSTEM FOR KINETIC DETERMINATIONS BASED ON THE USE OF 2 SERIAL INJECTION VALVES [J].
FERNANDEZ, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYST, 1987, 112 (06) :803-807
[4]   FORMATION OF 2 REACTION ZONES IN FLOW-INJECTION SYSTEMS FOR KINETIC DETERMINATIONS OF COBALT AND NICKEL [J].
FERNANDEZ, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICA CHIMICA ACTA, 1987, 193 :107-118
[5]   FLOW INJECTION ANALYSIS .8. DETERMINATION OF GLUCOSE IN BLOOD-SERUM WITH GLUCOSE DEHYDROGENASE [J].
HANSEN, EH ;
RUZICKA, J ;
RIETZ, B .
ANALYTICA CHIMICA ACTA, 1977, 89 (02) :241-254
[6]   CONTINUOUS-FLOW KINETIC TECHNIQUES IN FLOW-INJECTION ANALYSIS [J].
HOOLEY, DJ ;
DESSY, RE .
ANALYTICAL CHEMISTRY, 1983, 55 (02) :313-320
[7]   CHEMICAL-KINETICS WITH REAGENT DISPERSION IN SINGLE-LINE FLOW-INJECTION SYSTEMS [J].
HUNGERFORD, JM ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :1-19
[8]   KINETIC DETERMINATION OF MAGNESIUM AND CALCIUM BY STOPPED-FLOW INJECTION-ANALYSIS [J].
KAGENOW, H ;
JENSEN, A .
ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) :125-133
[9]   STOPPED FLOW AND MERGING ZONES - NEW APPROACH TO ENZYMATIC ASSAY BY FLOW INJECTION ANALYSIS [J].
RUZICKA, J ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1979, 106 (02) :207-224
[10]   FLOW-INJECTION ANALYSIS, PRINCIPLES, APPLICATIONS AND TRENDS [J].
RUZICKA, J ;
HANSEN, EH .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :19-44