COMPARISON OF TRANSVAGINAL AND TRANSABDOMINAL ULTRASOUND FOR MONITORING FOLLICULAR DEVELOPMENT IN AN INVITRO FERTILIZATION PROGRAM

被引:6
作者
BELAISCHALLART, J
DUFETRE, C
ALLART, JP
DEMOUZON, J
机构
[1] Department of Obstetrics and Gynaecology, Hôpital Boucicaut
[2] Clinique la Roseraie
[3] INSERM Unité 292, Hôpital Bicôtre
关键词
SONOGRAPHY; VAGINAL ROUTE; ABDOMINAL ROUTE; SONOGRAPHY TECHNIQUES; FOLLICULAR MONITORING;
D O I
10.1093/oxfordjournals.humrep.a137408
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Although nowadays most oocyte retrievals for in-vitro fertilization (IVF) are performed using a transvaginal, ultrasound-directed technique, monitoring of follicular development is still often performed via the abdominal route. On the basis of 106 sonographies carried out on 71 patients during ovulation monitoring within an IVF programme, we demonstrated that the number of follicles visualized endovaginally was significantly higher than that visualized by the abdominal route: n = 1124 versus n = 772 respectively, and that their size was significantly greater using the transvaginal approach: 20.8 mm versus 18.8 mm respectively, for the largest follicle. Consequently, if ovulation monitoring is carried out transvaginally, the follicular size criteria on which human chorionic gonadotrophin is administered must be reconsidered.
引用
收藏
页码:688 / 689
页数:2
相关论文
共 6 条
[1]  
Feichtinger W., Kemeter P., Transvaginalsector scan sonography for needle guided transvaginal follicle aspiration and other applications in gynecologic routine in and research. Fertil, Steril., 45, pp. 722-725, (1986)
[2]  
Gonzales C., Curson R., Parson J., Transabdominal versus transvaginalultrasound scanning of ovarian follicles: Are they comparable? Fertil, Steril., 50, pp. 657-659, (1988)
[3]  
Hackeloer B.J., Ultrsound scanning of the ovarian cycle, J. in Vitro, 1, pp. 217-220, (1984)
[4]  
Lavy G., Diamond M., Nero F., Shark K., De Cherney A., Transvaginaland transabdominal ultrasound for monitoring of follicular development in an in vitro fertilization and embryo transfer program: Patient response, J. in Vitro, 4, pp. 293-295, (1987)
[5]  
Prins G., Vogelzang R., Inherent sources of ultrasound variability in relation to follicular measurements, J. in Vitro, 1, pp. 221-225, (1984)
[6]  
Yee B., Barnes R., Vargyas J., Marrs R., Correlation of transabdominal and transvaginal ultrasound measurements of follicle size and number with laparoscopic findings for in vitro fertilization. Fertil, Steril., 47, pp. 828-832, (1987)