Diagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients

被引:6
作者
Li, Yifan [4 ]
Carpenter, Christopher R. [5 ]
Nicholson, Kathryn [6 ]
Milne, William Ken [1 ,2 ,3 ]
机构
[1] South Huron Hosp Assoc, 24 Huron St W, Exeter, ON N0M 1S2, Canada
[2] Univ Western Ontario, Schulich Sch Med & Dent, Dept Med, Goderich, ON, Canada
[3] South Huron Hosp Assoc, Dept Emergency Med, Exeter, ON, Canada
[4] Univ Western Ontario, Windsor Program, Schulich Sch Med & Dent, Windsor, ON, Canada
[5] Washington Univ, St Louis Sch Med, Div Emergency Med, St Louis, MO USA
[6] Univ Western Ontario, Schulich Sch Med & Dent, Ctr Studies Family Med, Dept Epidemiol & Biostat, London, ON, Canada
关键词
glaucoma; iCare rebound tonometer; IOP; Perkins applanation tonometer; rural; screening;
D O I
10.1515/dx-2015-0026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Vision health is recognized as a critical unmet need in North America. The ocular morbidity associated with glaucoma results from increased intraocular pressure (IOP) and early detection is crucial for the management of glaucoma. Our objective was to find a diagnostically accurate screening tool for intraocular hypertension that can be used in rural communities. We sought to validate the diagnostic accuracy of the iCare rebound tonometer against the gold standard Perkins applanation tonometer (PAT) in measuring IOP. Methods: Patients from two rural communities in Ontario, Canada visiting their optometrists for routine appointments had their IOP measured by a non-contact tonometer (NCT), an iCare rebound tonometer, and a Perkins applanation tonometer (PAT). Values of sensitivity, specificity, and likelihood ratios for a positive and negative result were calculated for the iCare and the NCT. Results: Complete data was collected from 209 patients. Overall, the iCare tonometer had high levels of validity, as compared to the gold standard PAT. The iCare tonometer displayed excellent sensitivity of 98.3% (90-99%, 95% CI) and excellent negative likelihood ratio of 0.024 (0.0088-0.066, 95% CI) which is useful for ruling out intraocular hypertension. Conclusions: The iCare tonometer is a reasonably valid tool for detecting elevated IOP. Its ease of use, simplicity, and accessibility makes it a good screening tool to improve eye health in rural areas.
引用
收藏
页码:227 / 234
页数:8
相关论文
共 50 条
[31]   Intraocular pressure measurement using ICare rebound tonometer in different positions of eye and different locations on cornea [J].
Wongwanwatana, Sirada ;
Treesit, Isaraporn ;
Funarunart, Panrapee ;
Iemsomboon, Wallop ;
Choontanom, Raveewan .
MEDICINE, 2023, 102 (36) :E34874
[32]   Analysis of reproducibility, evaluation, and preference of the new iC100 rebound tonometer versus iCare PRO and Perkins portable applanation tonometry [J].
Molero-Senosiain, Mercedes ;
Morales-Fernandez, Laura ;
Saenz-Frances, Federico ;
Garcia-Feijoo, Julian ;
Maria Martinez-de-la-Casa, Jose .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (06) :1349-1355
[33]   A new rebound tonometer for home monitoring of intraocular pressure [J].
André Rosentreter ;
Kerstin S. Jablonski ;
Anne C. Mellein ;
Stergiani Gaki ;
Arno Hueber ;
Thomas S. Dietlein .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 :1713-1719
[34]   Comparison of intraocular pressure in healthy brachycephalic and nonbrachycephalic cats using the Icare® TONOVET Plus rebound tonometer [J].
Kerdchuchuen, Kamolchanok ;
Samathayanon, Kingkarn ;
Phientong, Pitchapa ;
Chattraphirat, Suprapha ;
Jaturakan, Orapun ;
Tuntivanich, Nalinee .
VETERINARY OPHTHALMOLOGY, 2021, 24 (05) :484-490
[35]   A new rebound tonometer for home monitoring of intraocular pressure [J].
Rosentreter, Andre ;
Jablonski, Kerstin S. ;
Mellein, Anne C. ;
Gaki, Stergiani ;
Hueber, Arno ;
Dietlein, Thomas S. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (11) :1713-1719
[36]   Central and peripheral intraocular pressure measured by a rebound tonometer [J].
Yamashita, Tsutomu ;
Miki, Atsushi ;
Ieki, Yoshiaki ;
Kiryu, Junichi ;
Yaoeda, Kiyoshi ;
Shirakashi, Motohiro .
CLINICAL OPHTHALMOLOGY, 2011, 5 :1113-1118
[37]   Accuracy of the ICare rebound tonometer in glaucomatous eyes with topical ocular hypotensive medication [J].
Diaz, Alberto ;
Yebra-Pimentel, Eva ;
Resua, Carlos Garcia ;
Gilino, Jorge ;
Jesus Giraldez, M. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (01) :29-34
[38]   A comparison of intraocular pressure values obtained using a Goldmann applanation tonometer and a handheld version of applanation resonance tonometer: A preliminary report [J].
Mulak, Malgorzata ;
Czak, Wojciech A. ;
Mimier, Malgorzata ;
Kaczmarek, Radoslaw .
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 27 (04) :481-485
[39]   Assessing biomechanical corrections: A comparison between Corvis ST and ICare tonometer for intraocular pressure measurement [J].
Alsabti, Zeina M. ;
Ahmed, Kawther A. ;
Mohsin, Thakir M. .
RESULTS IN OPTICS, 2023, 13
[40]   Precision and accuracy of the ICare tonometer - Peripheral and central IOP measurements by rebound tonometry [J].
Muttuvelu, Danson V. ;
Baggesen, Kirsten ;
Ehlers, Niels .
ACTA OPHTHALMOLOGICA, 2012, 90 (04) :322-326