Effect of rotation bump on removal torque of orthodontic mini-implants

被引:1
作者
Gansukh, Odontuya [1 ]
Jeong, Jong-Wha [1 ]
Kim, Jong-Wan [2 ]
Kim, Young-Kyun [2 ,3 ]
Lee, Jong-Ho [4 ,5 ]
Kim, Tae-Woo [1 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Orthodont, Seoul, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Dept Orthodont, Sect Dent, 82 Gumi Ro 173 Beon Gil, Seoul 463707, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Oral & Maxillofacial Surg, Sect Dent, Seoul, South Korea
[4] Seoul Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Seoul, South Korea
[5] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul, South Korea
关键词
Mini-implant; Rotation bump; Torque; Torque ratio; Angular momentum;
D O I
10.5125/jkaoms.2013.39.6.269
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. Materials and Methods: This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirtytwo mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits and were removed after two weeks and four weeks, respectively. The maximum insertion torque (MIT), maximum removal torque (MRT), torque ratio (TR) of MRT to MIT and removal angular momentum (RAM) were all measured at the time of removal. Results: There were no significant differences between the two groups in MIT and MRT at two weeks or four weeks. However, TR and RAM at four weeks in the RB group were significantly higher than in the control group (P<0.05). TR of the RB group was significantly increased at four weeks (P<0.05). In both groups, RAM at four weeks was significantly higher than at two weeks (P<0.05). Conclusion: These results suggest that RB of the mini-implant could provide resistance to the removal rotation, although it did not increase the MRT.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 18 条
[1]   Histomorphometric Analysis and Removal Torque of Small Diameter Implants With Alternative Surface Treatments and Different Designs [J].
Ahn, Su-Jin ;
Leesungbok, Richard ;
Lee, Suk-Won .
JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (04) :263-272
[2]   Mechanical properties of self-drilling orthodontic micro-implants with different diameters [J].
Chen, Yan ;
Kyung, Hee Moon ;
Gao, Limin ;
Yu, Won-Jae ;
Bae, Eun-Ju ;
Kim, Sang-Min .
ANGLE ORTHODONTIST, 2010, 80 (05) :821-827
[3]   Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing [J].
Consolo, Ugo ;
Travaglini, Domenico ;
Todisco, Marzio ;
Trisi, Paolo ;
Galli, Silvia .
JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (03) :860-865
[4]  
Costa A, 1998, Int J Adult Orthodon Orthognath Surg, V13, P201
[5]  
Herrmann I, 2005, INT J ORAL MAX IMPL, V20, P220
[6]  
Kim JW, 2008, ANGLE ORTHOD, V78, P692, DOI 10.2319/0003-3219(2008)078[0692:COSBCA]2.0.CO
[7]  
2
[8]   Histomorphometric and mechanical analyses of the drill-free screw as orthodontic achorage [J].
Kim, JW ;
Ahn, SJ ;
Chang, YI .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (02) :190-194
[9]   Rotational Resistance of Surface-Treated Mini-implants [J].
Kim, Seong-Hun ;
Lee, Shin-Jae ;
Cho, Il-Sik ;
Kim, Seong-Kyun ;
Kim, Tae-Woo .
ANGLE ORTHODONTIST, 2009, 79 (05) :899-907
[10]   Effects of Microgrooves on the Success Rate and Soft Tissue Adaptation of Orthodontic Miniscrews [J].
Kim, Tae-Woo ;
Baek, Seung-Hak ;
Kim, Jong-Wan ;
Chang, Young-Il .
ANGLE ORTHODONTIST, 2008, 78 (06) :1057-1064