LEAST ABSOLUTE VALUE BASED ON LINEAR-PROGRAMMING ALGORITHM FOR MEASUREMENT OF POWER-SYSTEM FREQUENCY FROM A DISTORTED BUS VOLTAGE SIGNAL

被引:7
作者
SOLIMAN, SA
CHRISTENSEN, GS
KELLY, DH
ELNAGGAR, KM
机构
[1] Electrical Power and Machines Department, Ain Shams University Abbassia, Cairo
[2] Electrical Engineering Department, The University of Alberta, Alberta
来源
ELECTRIC MACHINES AND POWER SYSTEMS | 1992年 / 20卷 / 06期
关键词
FREQUENCY RELAYING; DISTORTED BUS VOLTAGE; DIGITAL CONTROL; PARAMETER ESTIMATION;
D O I
10.1080/07313569208909620
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the application of least absolute value based on linear programming for measurement of the steady state frequency drift of power systems from a distorted bus voltage signal. Different models are developed in this paper, depending on the number of harmonics in the bus voltage signal, and also the number of terms truncated from Taylor series expansion. The proposed technique uses the digitized samples of the bus voltage at the relay location. In this paper, we assume that the frequency is constant during the data window size. Effects of sampling frequency, data window size and number of harmonics chosen for modelling the voltage signal on the estimate are also investigated.
引用
收藏
页码:549 / 568
页数:20
相关论文
共 12 条
[1]  
Sachde M.S., Nagpa H., A recursive least error square algorithm for power system relaying and measurement applications, IEEE Trans, 6, 3, pp. 1008-1101, (1991)
[2]  
Girgis A., Chang W.B., Makram E.B., A digital recursive measurement scheme for on-line tracking of power system harmonics, IEEE Trans, on Power Delivery, 6, 3, pp. 1153-1160, (1991)
[3]  
Sachdev M.S., Giray M.M., A least error squares technique for determining power system frequency, IEEE, 104, 2, pp. 437-444, (1985)
[4]  
Sachdev M.S., Giray M.M., Measurement of local frequency from digitized bus voltage samples, Trans, 23, pp. 84-149, (1984)
[5]  
Sachdev M.S., Giray M.M., Amplitude and frequency measurement by discrete fourier transform, Tran. CEA, Power, 24
[6]  
Phadke A.G., Thorp J.S., Adamiak M.G., A new measurement technique for tracking voltage phasors, local system frequency, and rate of change of, IEE, 5, pp. 1025-1038, (1983)
[7]  
Soliman S.A., G.S. Christensen A New Technique For Curve Fitting Based On Minimum Absolute Deviations, Statistics & Data Analysis, 6, 4, pp. 341-351, (1988)
[8]  
Girgis A.A., Daniel Hwang T.L., Optimal estimation of voltage phasors and frequency deviation using linear and non-linear kalman filtering: Theory and limitations, IEEE, (1984)
[9]  
Sachdev M.S., Wood H.C., Johanson N.G., –kalman filtering applied to power system measurements for relaying—, trans, on power apparatus and systems, vol, PAS-104, 12, pp. 3565-3575, (1985)
[10]  
Giray M.M., –A Least Error Squares Technique for Estimating the Magnitude and the Frequency of a Voltage Signal—, (1986)