The influences of wall effects and saturation of the gas multiplication on position resolutions of position-sensitive He-3 proportional counters have been studied by means of numerical calculations, computer simulations and experiments. When the proton produced by the He-3(n,p)t reaction loses its specific energy in a counter wall by wall effects, a good position resolution is obtained escaping from any effects of a finite range of the proton and the triton. In the case where the gas multiplication is saturated, the best position resolution is obtained by selecting low pulse height events that the protons and the tritons move perpendicularly to the anode wire.
引用
收藏
页码:286 / 290
页数:5
相关论文
共 50 条
  • [31] POSITION-SENSITIVE GAS PROPORTIONAL CHAMBERS
    MORRIS, CL
    THIESSEN, HA
    HOFFMANN, GW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 141 - 143
  • [32] PROPORTIONAL COUNTER AS A POSITION-SENSITIVE DEVICE
    BRAID, TH
    PROCEEDINGS OF THE ROYAL SOCIETY OF EDINBURG SECTION A-MATHEMATICAL AND PHYSICAL SCIENCES, 1972, 70 : 9 - &
  • [33] POSITION-SENSITIVE PROPORTIONAL COUNTER FOR NEUTRONS
    GALTSOV, VS
    ZAKHARKIN, II
    KUZNETSOV, VA
    SHCHETININ, OI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (02) : 374 - 376
  • [34] RC-ENCODING FOR POSITION-SENSITIVE PROPORTIONAL-COUNTERS USING LOW-RESISTANCE, METAL WIRE ANODE AND ACTIVE LOAD CAPACITANCE
    KOPP, MK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1979, 50 (03): : 382 - 383
  • [35] A LONG AND SLENDER POSITION-SENSITIVE HE-3 PROPORTIONAL COUNTER WITH AN ANODE WIRE SUPPORTED BY A LADDER-SHAPED SOLID INSULATOR
    URITANI, A
    KUNIYA, Y
    TAKENAKA, Y
    TOYOKAWA, H
    YAMANE, Y
    MORI, C
    KOBAYASHI, K
    SHIROYA, S
    ICHIHARA, C
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1995, 32 (08) : 719 - 726
  • [36] TEMPERATURE-DEPENDENCE OF THERMAL-NEUTRON DETECTION PERFORMANCE OF HE-3 PROPORTIONAL-COUNTERS
    SAKAI, E
    KUBO, K
    YOSHIDA, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 776 - 782
  • [37] MEASUREMENTS OF THE X-RAY TRANSMISSION TOPOGRAPHY ON RADIATION ENTRANCE WINDOWS FOR THE POSITION-SENSITIVE PROPORTIONAL-COUNTERS ON BOARD THE GERMAN ASTRONOMY SATELLITE ROSAT
    STEPHAN, KH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 717 - 720
  • [38] CHARGE INTEGRATING POSITION-SENSITIVE PROPORTIONAL CHAMBER
    MOCHIKI, K
    HASEGAWA, K
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C411 - C411
  • [39] 2-DIMENSIONAL-POSITION-SENSITIVE MULTIWIRE PROPORTIONAL-COUNTERS WITH HELICALLY-WOUND RIBBON CATHODES
    BRAITHWAITE, WJ
    MORRIS, CL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (04): : 632 - 632
  • [40] Neutron spectrometry with He-3 proportional counters
    Manolopoulou, M.
    Fragopoulou, M.
    Stoulos, S.
    Vagena, E.
    Westmeier, W.
    Zamani, M.
    XIX INTERNATIONAL SCHOOL ON NUCLEAR PHYSICS, NEUTRON PHYSICS AND APPLICATIONS (VARNA 2011), 2012, 366