A STUDY ON THE POSITION RESOLUTION OF POSITION-SENSITIVE HE-3 PROPORTIONAL-COUNTERS

被引:1
|
作者
URITANI, A
MARNADA, N
TAKENAKA, Y
MORI, C
MIYAHARA, H
机构
[1] Department of Nuclear Engineering, School of Engineering, Nagoya University, Nagoya
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1994年 / 350卷 / 1-2期
关键词
D O I
10.1016/0168-9002(94)91175-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The influences of wall effects and saturation of the gas multiplication on position resolutions of position-sensitive He-3 proportional counters have been studied by means of numerical calculations, computer simulations and experiments. When the proton produced by the He-3(n,p)t reaction loses its specific energy in a counter wall by wall effects, a good position resolution is obtained escaping from any effects of a finite range of the proton and the triton. In the case where the gas multiplication is saturated, the best position resolution is obtained by selecting low pulse height events that the protons and the tritons move perpendicularly to the anode wire.
引用
收藏
页码:286 / 290
页数:5
相关论文
共 50 条
  • [21] HIGH-RESOLUTION POSITION-SENSITIVE PROPORTIONAL COUNTER
    ROBERTSON, RGH
    MARKHAM, RG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (04): : 601 - 602
  • [22] HIGH-RESOLUTION POSITION-SENSITIVE PROPORTIONAL COUNTER
    MARKHAM, RG
    ROBERTSON, RGH
    NUCLEAR INSTRUMENTS & METHODS, 1975, 129 (01): : 131 - 140
  • [23] RESOLUTION OF A POSITION-SENSITIVE 10-BF3 PROPORTIONAL COUNTER
    WESTPHAL, GP
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (02): : 279 - 283
  • [24] USE OF LINEAR POSITION-SENSITIVE PROPORTIONAL-COUNTERS FOR DIFFUSE SMALL-ANGLE SYNCHROTRON RADIATION SCATTERING OF BIOPOLYMER SOLUTIONS
    VAZINA, AA
    GADJIEV, AM
    MATYUSHIN, AM
    FELDMAN, IG
    KHABAKHPASHEV, AG
    KHLESTOV, VB
    SHEROMOV, MA
    BIOFIZIKA, 1977, 22 (02): : 351 - 352
  • [25] A POSITION-SENSITIVE PROPORTIONAL COUNTER
    SCOBIE, J
    AMERICAN JOURNAL OF PHYSICS, 1969, 37 (01) : 107 - &
  • [26] SIMPLE EFFICIENT METHOD OF DELAY-LINE TERMINATION AND TIMING-SIGNALS EXTRACTION IN POSITION-SENSITIVE PROPORTIONAL-COUNTERS
    BIRK, M
    BRESKIN, A
    TRAUTNER, N
    NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (02): : 393 - 395
  • [27] POSITION-SENSITIVE PROPORTIONAL COUNTER
    SPROSS, RL
    KENEFICK, RA
    HENSLEY, JR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 618 - 618
  • [28] PILEUP EFFECTS IN THE APPLICATION OF HE-3 PROPORTIONAL-COUNTERS TO DOSE EQUIVALENT DETERMINATION
    LUCAS, AC
    HEALTH PHYSICS, 1979, 37 (06): : 824 - 824
  • [29] A POSITION-SENSITIVE DETECTOR SYSTEM CONSISTING OF AN ARRAY OF MINI-PROPORTIONAL COUNTERS
    VANBEEK, HF
    BOELEE, A
    VANDERLAAN, JJM
    MELS, WA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) : 791 - 794
  • [30] EFFICIENCY AND POSITION-RESOLUTION OF 2-DIMENSIONAL POSITION-SENSITIVE MULTIWIRE PROPORTION COUNTERS
    BOLGER, JE
    BRAITHWAITE, WJ
    HOLTKAMP, DB
    KALLNE, J
    THIESSEN, HA
    MORRIS, CL