BONE-DENSITY AFTER RIGID PLATE FIXATION OF TIBIAL FRACTURES - A DUAL-ENERGY X-RAY ABSORPTIOMETRY STUDY

被引:25
作者
JANES, GC [1 ]
COLLOPY, DM [1 ]
PRICE, R [1 ]
SIKORSKI, JM [1 ]
机构
[1] SIR CHARLES GAIRDNER HOSP,DEPT ENDOCRINOL,BONE STRUCT UNIT,NEDLANDS,WA 6009,AUSTRALIA
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1993年 / 75卷 / 06期
关键词
D O I
10.1302/0301-620X.75B6.8245081
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We used dual-energy X-ray absorptiometry (DEXA) to measure the bone mineral content (BMC) of both tibiae in 13 patients who had been treated for a tibial fracture by rigid plate fixation, Within two weeks of plate removal the BMC was significantly greater in the bone that had been under the plate than at the same site in the control tibia, An unplated area of bone near the ankle showed a significant decrease in BMC at the time of plate removal with subsequent return to the level of the control tibia during the ensuing 18 months. We conclude that osteoinductive influences out weigh the potential causes of osteopenia, such as stress shielding and disuse, and that, contrary to expectation, demineralisation is not a factor in the diminished strength of the tibia after plating for fracture.
引用
收藏
页码:914 / 917
页数:4
相关论文
共 22 条
  • [1] EFFECTS OF RIGIDITY OF INTERNAL-FIXATION PLATES ON LONG BONE REMODELING - BIOMECHANICAL AND QUANTITATIVE HISTOLOGICAL STUDY
    AKESON, WH
    WOO, SLY
    RUTHERFORD, L
    COUTTS, RD
    GONSALVES, M
    AMIEL, D
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1976, 47 (03): : 241 - 249
  • [2] BUCKWALTER JA, 1991, ROCKWOOD GREENS FRAC, V1, P181
  • [3] THE PLATED FEMUR - RELATIONSHIPS BETWEEN THE CHANGES IN BONE STRESSES AND BONE LOSS
    CARTER, DR
    VASU, R
    HARRIS, WH
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (03): : 241 - 248
  • [4] CARTER DR, 1984, J ORTHOPAED RES, V2, P80
  • [5] X-RAY DUAL-PHOTON ABSORPTIOMETRY - A NEW METHOD FOR THE MEASUREMENT OF BONE-DENSITY
    CULLUM, ID
    ELL, PJ
    RYDER, JP
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (739) : 587 - 592
  • [6] COMPARATIVE-ASSESSMENT OF DUAL-PHOTON ABSORPTIOMETRY AND DUAL-ENERGY RADIOGRAPHY
    GLUER, CC
    STEIGER, P
    SELVIDGE, R
    ELLIESENKLIEFOTH, K
    HAYASHI, C
    GENANT, HK
    [J]. RADIOLOGY, 1990, 174 (01) : 223 - 228
  • [7] LAFTMAN P, 1989, ACTA ORTHOP SCAND, V60, P718
  • [8] RECOVERY OF DIAPHYSEAL BONE STRENGTH AFTER RIGID INTERNAL PLATE FIXATION - AN EXPERIMENTAL-STUDY IN THE RABBIT
    LAFTMAN, P
    SIGURDSSON, F
    STROMBERG, L
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (02): : 215 - 222
  • [9] EFFECTS ON INTACT FEMORA OF DOGS OF APPLICATION AND REMOVAL OF METAL PLATES - METABOLIC AND STRUCTURAL STUDY COMPARING STIFFER AND MORE FLEXIBLE PLATES
    MOYEN, BJL
    LAHEY, PJ
    WEINBERG, EH
    HARRIS, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (07) : 940 - 947
  • [10] PAAVOLAINEN P, 1978, CLIN ORTHOP RELAT R, V136, P287