MUSIC Algorithm for Respiratory Rate Estimation Using RF Signals

被引:6
作者
Uysal, Can [1 ]
Filik, Tansu [1 ]
机构
[1] Anadolu Univ, Sch Engn, Dept Elect & Elect Engn, Eskisehir, Turkey
来源
ELECTRICA | 2018年 / 18卷 / 02期
关键词
MUSIC; contactless; respiratory rate; wireless signals; software defined radios;
D O I
10.26650/electrica.2018.03405
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Continuous monitoring of respiratory rate (cycle) during sleep for diseases such as sleep apnea and sudden infant death syndrome (SIDS) can be lifesaving. Wireless radio communications signals are everywhere and can be harnessed for contactless monitoring of the respiratory rates.The amplitude of the received signal strength changes periodically depending on the exhalation and inhalation of the subject. In this paper, subspace-based multiple signal classification (MUSIC) algorithm is applied to estimate the respiratory rate for better results. The proposed method and the other power spectral density (PSD) methods for respiratory estimations are compared with the real laboratory measurements. It is demonstrated that the proposed method estimates the respiratory rate with high accuracy and outperforms the other PSD-based methods which are commonly used in the literature.
引用
收藏
页码:300 / 309
页数:10
相关论文
共 32 条
[1]   Smart Homes that Monitor Breathing and Heart Rate [J].
Adib, Fadel ;
Mao, Hongzi ;
Kabelac, Zachary ;
Katabi, Dina ;
Miller, Robert C. .
CHI 2015: PROCEEDINGS OF THE 33RD ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, 2015, :837-846
[2]   Respiration Rate Monitoring Methods: A Review [J].
AL-Khalidi, F. Q. ;
Saatchi, R. ;
Burke, D. ;
Elphick, H. ;
Tan, S. .
PEDIATRIC PULMONOLOGY, 2011, 46 (06) :523-529
[3]   A New Measurement Method Based on Music Algorithm for Through-the-Wall Detection of Life Signs [J].
Ascione, Marcello ;
Buonanno, Aniello ;
D'Urso, Michele ;
Angrisani, Leopoldo ;
Lo Moriello, Rosario Schiano .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (01) :13-26
[4]  
Bartula M, 2013, IEEE ENG MED BIO, P2672, DOI 10.1109/EMBC.2013.6610090
[5]   Breathing detection:: Towards a miniaturized, wearable, battery-operated monitoring system [J].
Corbishley, Phil ;
Rodriguez-Villegas, Esther .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (01) :196-204
[6]   THE IDENTIFICATION OF MULTIPLE OUTLIERS [J].
DAVIES, L ;
GATHER, U .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1993, 88 (423) :782-792
[7]   Signal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate Measurements [J].
Droitcour, Amy D. ;
Boric-Lubecke, Olga ;
Kovacs, Gregory T. A. .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2009, 57 (10) :2498-2507
[8]   Accuracy of respiratory rate monitoring by capnometry using the Capnomask® in extubated patients receiving supplemental oxygen after surgery [J].
Gaucher, A. ;
Frasca, D. ;
Mimoz, O. ;
Debaene, B. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (02) :316-320
[9]  
Hernandez J., 2015, EAI END T PERV HLTH, V15
[10]  
Kaltiokallio O, 2014, PROCEEDINGS OF THE 13TH INTERNATIONAL SYMPOSIUM ON INFORMATION PROCESSING IN SENSOR NETWORKS (IPSN' 14), P59, DOI 10.1109/IPSN.2014.6846741