DEXTRAN-MAGNETITE PARTICLES - CONTRAST-ENHANCED MRI OF BLOOD-BRAIN-BARRIER DISRUPTION IN A RAT MODEL

被引:29
作者
BULTE, JWM
DEJONGE, MWA
KAMMAN, RL
GO, KG
ZUIDERVEEN, F
BLAAUW, B
OOSTERBAAN, JA
THE, TH
DELEIJ, L
机构
[1] UNIV GRONINGEN, DEPT MAGNET RESONANCE, 9717 EZ GRONINGEN, NETHERLANDS
[2] UNIV GRONINGEN, DEPT NEUROSURG, 9717 EZ GRONINGEN, NETHERLANDS
[3] UNIV GRONINGEN, DEPT HIST, 9717 EZ GRONINGEN, NETHERLANDS
[4] UNIV GRONINGEN, DEPT CELL BIOL, 9717 EZ GRONINGEN, NETHERLANDS
关键词
D O I
10.1002/mrm.1910230203
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dextran‐magnetite particles (DMP) were studied for their use as a MR contrast agent to visualize lesions with a blood‐brain barrier (bbb) disruption. A freezing injury to the rat cerebral cortex was used as a model of bbb disruption. The biodistribution of iv‐injected DMP was studied using atomic absorption spectrophotometry, electron microscopy, and MRI. One hour after injection, focal accumulation of the particles in capillary endothelial cells could be demonstrated in the freezing lesion. Despite the observation that the relaxivity of DMP in vivo appears to be less well pronounced than that in vitro, the MR imaging studies show that DMP can be used to visualize bbb disruption with adequate contrast. © 1992 Academic Press, Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:215 / 223
页数:9
相关论文
共 18 条
[1]  
BACON BR, 1987, J LAB CLIN MED, V110, P164
[2]  
CLASEN RA, 1953, SURG GYNECOL OBSTET, V96, P605
[3]   FERROMAGNETIC PARTICLES AS CONTRAST AGENTS FOR MAGNETIC-RESONANCE-IMAGING OF LIVER AND SPLEEN [J].
DIAS, MHM ;
LAUTERBUR, PC .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :328-330
[4]   TRANSVERSE RELAXATION OF SOLVENT PROTONS INDUCED BY MAGNETIZED SPHERES - APPLICATION TO FERRITIN, ERYTHROCYTES, AND MAGNETITE [J].
GILLIS, P ;
KOENIG, SH .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (04) :323-345
[5]   ASSESSMENT OF A SUPERPARAMAGNETIC IRON-OXIDE (AMI-25) AS A BRAIN CONTRAST AGENT [J].
KENT, TA ;
QUAST, MJ ;
KAPLAN, BJ ;
LIFSEY, RS ;
EISENBERG, HM .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (03) :434-443
[6]   MEASUREMENT OF IRON IN LIVER BIOPSIES - A COMPARISON OF 3 ANALYTICAL METHODS [J].
KREEFTENBERG, HG ;
KOOPMAN, BJ ;
HUIZENGA, JR ;
VANVILSTEREN, T ;
WOLTHERS, BG ;
GIPS, CH .
CLINICA CHIMICA ACTA, 1984, 144 (2-3) :255-262
[7]   STUDIES OF DIFFUSION IN RANDOM-FIELDS PRODUCED BY VARIATIONS IN SUSCEPTIBILITY [J].
MAJUMDAR, S ;
GORE, JC .
JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01) :41-55
[8]   A QUANTITATIVE STUDY OF RELAXATION RATE ENHANCEMENT PRODUCED BY IRON-OXIDE PARTICLES IN POLYACRYLAMIDE GELS AND TISSUE [J].
MAJUMDAR, S ;
ZOGHBI, S ;
POPE, CF ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (02) :185-202
[9]   THE INFLUENCE OF PULSE SEQUENCE ON THE RELAXATION EFFECTS OF SUPERPARAMAGNETIC IRON-OXIDE CONTRAST AGENTS [J].
MAJUMDAR, S ;
ZOGHBI, SS ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1989, 10 (03) :289-301
[10]   IMMUNOSPECIFIC FERROMAGNETIC IRON-DEXTRAN REAGENTS FOR THE LABELING AND MAGNETIC SEPARATION OF CELLS [J].
MOLDAY, RS ;
MACKENZIE, D .
JOURNAL OF IMMUNOLOGICAL METHODS, 1982, 52 (03) :353-367