MINIATURE LIQUID JUNCTION REFERENCE ELECTRODE WITH MICROMACHINED SILICON CAVITY

被引:31
|
作者
YEE, S [1 ]
JIN, H [1 ]
LAM, LKC [1 ]
机构
[1] UNIV WASHINGTON,DEPT ELECT ENGN,SEATTLE,WA 98195
来源
SENSORS AND ACTUATORS | 1988年 / 15卷 / 04期
关键词
This work is supported Washington; contract; #65-5083;
D O I
10.1016/0250-6874(88)81504-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
9
引用
收藏
页码:337 / 345
页数:9
相关论文
共 50 条
  • [41] Plastic Deformation of Micromachined Silicon Diaphragms with a Sealed Cavity at High Temperatures
    Ren, Juan
    Ward, Michael
    Kinnell, Peter
    Craddock, Russell
    Wei, Xueyong
    SENSORS, 2016, 16 (02)
  • [42] A micromachined millimeter-wave cavity resonator on silicon and quartz substrates
    Song, Ki-Jae
    Yoon, Bup-Sang
    Lee, Jong-Chul
    Lee, Byungje
    Kim, Jong-Heon
    Kim, Nam-Young
    Park, Jae-Yeong
    Kim, Geun-Ho
    Bu, Jong-Uk
    Japanese Journal of Applied Physics, Part 2: Letters, 2001, 40 (12 B):
  • [43] A screen-printed three-electrode-type sticker device with an accurate liquid junction-type reference electrode
    Shitanda, Isao
    Miyazaki, Kaishi
    Loew, Noya
    Esaka, Ryosuke
    Hoshi, Yoshinao
    Itagaki, Masayuki
    CHEMICAL COMMUNICATIONS, 2021, 57 (23) : 2875 - 2878
  • [44] A review of the history and technology of micromachined miniature displays using foundry produced silicon backplanes
    Walton, AJ
    Vass, DG
    Underwood, I
    Bodammer, G
    Calton, DW
    Seunarine, K
    Stevenson, JTM
    Gundlach, AM
    DEVICE AND PROCESS TECHNOLOGIES FOR MEMS AND MICROELECTRONICS, 1999, 3892 : 26 - 38
  • [45] A review of the history and technology of micromachined miniature displays using foundry produced silicon backplanes
    Walton, AJ
    Vass, DG
    Underwood, I
    Bodammer, G
    Calton, DW
    Seunarine, K
    Stevenson, JTM
    Gundlach, AM
    DESIGN, CHARACTERIZATION, AND PACKAGING FOR MEMS AND MICROELECTRONICS, 1999, 3893 : 26 - 38
  • [46] Planer-type liquid junction Ag/AgCl reference electrode and its application in a potentiometric biosensor
    Liao, WY
    Lin, HY
    Chou, TC
    2005 IEEE 31ST ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2005, : 225 - 226
  • [47] IMPROVEMENTS IN THE PRECISION OF PH MEASUREMENTS - A LABORATORY REFERENCE ELECTRODE WITH RENEWABLE FREE-DIFFUSION LIQUID JUNCTION
    COVINGTON, AK
    WHALLEY, PD
    DAVISON, W
    ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) : 221 - 229
  • [48] A review of the history and technology of micromachined miniature displays using foundry produced silicon backplanes
    Walton, AJ
    Vass, DG
    Underwood, I
    Bodammer, G
    Calton, DW
    Seunarine, K
    Stevenson, JTM
    Gundlach, AM
    ELECTRONICS AND STRUCTURES FOR MEMS, 1999, 3891 : 26 - 38
  • [50] Needle-type Ag/AgI reference electrode with a stagnant electrolyte layer and an active liquid junction
    Hashimoto, Masatoshi
    Upadhyay, Sanjay
    Kojima, Shimpey
    Suzuki, Hiroaki
    Hayashi, Katsuyoshi
    Sunagawa, Kenji
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2006, 153 (07) : H155 - H160