COMPARISON OF AORTIC PULSE-WAVE CONTOUR ANALYSIS AND THERMODILUTION METHODS OF MEASURING CARDIAC-OUTPUT DURING ANESTHESIA IN THE DOG

被引:11
作者
ENGLISH, JB [1 ]
HODGES, MR [1 ]
SENTKER, C [1 ]
JOHANSEN, R [1 ]
STANLEY, TH [1 ]
机构
[1] UNIV UTAH,COLL MED,DEPT ANESTHESIOL,SALT LAKE CITY,UT 84112
关键词
D O I
10.1097/00000542-198001000-00012
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:56 / 61
页数:6
相关论文
共 9 条
[1]   THE MEASUREMENT OF PULSATILE BLOOD FLOW BY THE COMPUTED PRESSURE GRADIENT TECHNIQUE [J].
FRY, DL .
IRE TRANSACTIONS ON MEDICAL ELECTRONICS, 1959, 6 (04) :259-264
[2]   MIS-APPLICATION OF WARNER METHOD FOR COMPUTER-ANALYSIS OF CARDIOVASCULAR VARIABLES [J].
HILBERMAN, M .
ANESTHESIOLOGY, 1977, 47 (04) :397-398
[3]  
JUARDO RA, 1973, SURGERY, V74, P358
[4]  
KOUCHOUKOS N T, 1969, Surgical Forum (Chicago), V20, P180
[5]   ESTIMATION OF STROKE VOLUME IN DOG BY A PULSE CONTOUR METHOD [J].
KOUCHOUKOS, NT ;
SHEPPARD, LC ;
MCDONALD, DA .
CIRCULATION RESEARCH, 1970, 26 (05) :611-+
[6]   EVALUATION OF SEVERAL METHODS FOR COMPUTING STROKE VOLUME FROM CENTRAL AORTIC PRESSURE [J].
STARMER, CF ;
MCHALE, PA ;
COBB, FR ;
GREENFIELD, JC .
CIRCULATION RESEARCH, 1973, 33 (02) :139-148
[7]   ROLE OF COMPUTERS IN MEDICAL RESEARCH [J].
WARNER, HR .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1966, 196 (11) :944-&
[8]   QUANTITATION OF BEAT-TO-BEAT CHANGES IN STROKE VOLUME FROM THE AORTIC PULSE CONTOUR IN MAN [J].
WARNER, HR ;
SWAN, HJC ;
CONNOLLY, DC ;
TOMPKINS, RG ;
WOOD, EH .
JOURNAL OF APPLIED PHYSIOLOGY, 1953, 5 (09) :495-507
[9]  
WARNER HR, 1968, CIRCULATION, V27, P68