AN ISFET GLUCOSE SENSOR WITH A SILICONE-RUBBER MEMBRANE FOR UNDILUTED SERUM MONITORING

被引:10
|
作者
SAITO, A [1 ]
ITO, N [1 ]
KUMURA, J [1 ]
KURIYAMA, T [1 ]
机构
[1] NEC CORP LTD,MICROELECTR RES LABS,MIYAMAE KU,KAWASAKI,KANAGAWA 216,JAPAN
关键词
D O I
10.1016/0925-4005(93)01195-A
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion-sensitive field-effect transistor (ISFET) glucose sensor with a silicone rubber membrane has been fabricated and its operation has been demonstrated in monitoring glucose concentration in serum and suction effusion fluid without dilution. The sensor characteristics are evaluated by measuring glucose concentrations in HEPES-NaOH buffers with different buffer capacities. The silicone membrane, which restricts glucose diffusion, expands the linear calibration range up to 500 mg/dl glucose. This membrane also restricts buffer species diffusion, so that the sensor output is not affected by solution buffer capacity. Moreover, investigation on the relationship between the sensor response and dissolved oxygen concentration shows that this sensor maintains constant outputs in solutions containing 1.5-7.5 ppm of oxygen. The sensor is mounted in a flow cell, into which serum samples and HEPES-NaOH buffer solution are alternately fed by a peristaltic pump. It takes 15 min to measure one sample. In 21 measurements on the same serum sample, the sensor output variance coefficient is found to be 4.7%. The sensor is applied to monitor glucose concentration in glucose-loaded rabbit suction effusion fluid. The glucose-level profile obtained by this sensor shows a good correlation with that measured by a conventional glucose analyser.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [1] ISFET GLUCOSE SENSOR FOR UNDILUTED SERUM SAMPLE MEASUREMENT
    SAITO, A
    MIYAMOTO, S
    KIMURA, J
    KURIYAMA, T
    SENSORS AND ACTUATORS B-CHEMICAL, 1991, 5 (1-4) : 237 - 239
  • [2] PERVAPORATION PERFORMANCE AND SWELLING BEHAVIOR OF SILICONE-RUBBER MEMBRANE
    IWATSUBO, T
    OGASAWARA, K
    MASUOKA, T
    MIZOGUCHI, K
    KAGAKU KOGAKU RONBUNSHU, 1994, 20 (05) : 666 - 670
  • [3] ENZYMATIC DETERMINATION OF SERUM UREA ON SURFACE OF SILICONE-RUBBER PADS
    KUAN, JCW
    LAU, HKY
    GUILBAULT, GG
    CLINICAL CHEMISTRY, 1975, 21 (01) : 67 - 70
  • [4] EFFECT OF SILICONE-RUBBER SURFACE ON THE CALCIUM BALANCE OF HUMAN SERUM
    ROSANOVA, I
    SEVASTIANOV, V
    KIM, SW
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (04): : 459 - 465
  • [5] AN ENZYME SENSOR FOR CONTINUOUS GLUCOSE MONITORING IN UNDILUTED BLOOD
    FISCHER, U
    ABEL, P
    FREYSE, EJ
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1983, 6 (03): : 168 - 168
  • [6] FLUOROMETRIC ENZYMATIC DETERMINATION OF SERUM CREATININE ON THE SURFACE OF SILICONE-RUBBER PADS
    CHEN, SP
    KUAN, SS
    GUILBAULT, GG
    CLINICAL CHEMISTRY, 1979, 25 (06) : 1069 - 1069
  • [7] TRANSPORT OF ETHANOL WATER DIMERS IN PERVAPORATION THROUGH A SILICONE-RUBBER MEMBRANE
    RADOVANOVIC, P
    THIEL, SW
    HWANG, ST
    JOURNAL OF MEMBRANE SCIENCE, 1990, 48 (01) : 55 - 65
  • [8] RELEASE OF NAPROXEN FROM COPRECIPITATES AND TRANSPORT THROUGH A SILICONE-RUBBER MEMBRANE
    ORIENTI, I
    ZECCHI, V
    CAVALLARI, C
    FINI, A
    ACTA PHARMACEUTICA TECHNOLOGICA-INTERNATIONAL JOURNAL OF DRUG FORUMLATION AND BIOPHARMACEUTICS, 1990, 36 (01): : 11 - 14
  • [9] BIOCOMPATIBILITY OF STANDARD AND SILICA-FREE SILICONE-RUBBER MEMBRANE OXYGENATORS
    FOUNTAIN, SW
    DUFFIN, J
    WARD, CA
    OSADA, H
    MARTIN, BA
    COOPER, JD
    AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 236 (02): : H371 - H375
  • [10] FLUOROMETRIC ENZYMATIC DETERMINATION OF SERUM CREATININE ON THE SURFACE OF SILICONE-RUBBER PADS
    CHEN, SP
    KUAN, SS
    GUILBAULT, GG
    CLINICA CHIMICA ACTA, 1980, 100 (01) : 21 - 31