ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM

被引:91
作者
BUTTS, K [1 ]
RIEDERER, SJ [1 ]
EHMAN, RL [1 ]
FELMLEE, JP [1 ]
GRIMM, RC [1 ]
机构
[1] MAYO CLIN & MAYO FDN,MAGNET RESONANCE LAB,200 1ST ST SW,ROCHESTER,MN 55905
关键词
LIVER NEOPLASMS; MR; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; ECHO PLANAR; RAPID IMAGING;
D O I
10.1148/radiology.189.1.8396785
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: A multisection, whole-body echo-planar imaging (EPI) sequence was developed to obtain T2-weighted images of the liver in one 18-second breath hold with a standard magnetic resonance (MR) imaging system. MATERIALS AND METHODS: This capability was achieved by dividing the data acquisition period into eight interleaved segments rather than one or two as implemented previously with EPI systems having high-power gradient subsystems. RESULTS: The interleaved echo-planar images had excellent depiction of anatomy and no identifiable respiratory artifact. In 26 lesions in 12 patients, the eight-shot echo-planar images (2,000/66 [repetition time msec/echo time msec]) had superior contrast compared with conventional T2-weighted spin-echo (SE) images (2,500/60) by an average factor of 1.22 +/- 0.31 (standard deviation) and an average contrast-to-noise ratio relative to conventional T2-weighted SE images of 0.85 +/- 0.22. CONCLUSION: With a conventional MR imaging system, breath-hold T2-weighted echo-planar images of the liver are comparable in diagnostic quality to conventional SE images.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 33 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]  
BUTTS RK, 1992, J MAGN RESON IMAGING, V2, P285
[3]  
CATASCA JC, 1992, RADIOLOGY, V185, P234
[4]   ULTRA-FAST IMAGING [J].
COHEN, MS ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IMAGING, 1991, 9 (01) :1-37
[5]   ECHO-PLANAR PEDIATRIC IMAGER [J].
CROOKS, LE ;
ARAKAWA, M ;
HYLTON, NM ;
AVRAM, H ;
HOENNINGER, JC ;
WATTS, JC ;
HALE, JD ;
KAUFMAN, L .
RADIOLOGY, 1988, 166 (01) :157-163
[6]   SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST [J].
EDELMAN, RR ;
WALLNER, B ;
SINGER, A ;
ATKINSON, DJ ;
SAINI, S .
RADIOLOGY, 1990, 177 (02) :515-521
[7]  
EDELSTEIN WA, 1984, Patent No. 4451788
[8]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[9]  
FARZANEH F, 1989, Magnetic Resonance Imaging, V7, P70
[10]  
FARZANEH F, 1988, RADIOLOGY P, V169, P379