Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella

被引:21
作者
Ali, Mohammed [1 ]
Kuiper, Jan [2 ]
John, Joby [3 ]
机构
[1] North Cumbria NHS Trust, Trauma & Orthopaed, Carlisle, England
[2] Robert Jones & Agnes Hunt Orthopaed Hosp, Oswestry, Shrops, England
[3] Univ Hosp Nottinghamshire, Nottingham, England
关键词
Patella transverse fractures; Tension band wiring; Biomechanical analysis;
D O I
10.1016/j.cjtee.2016.06.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Tension band wiring is commonly used for fixation of simple transverse fractures. The popular configuration is parallel Kirschner wires (K-wires) and a stainless steel wire loop placed in a vertically oriented figure-of-8. Methods: We used a wooden model of a patella with a midway transverse fracture and compared four different types of fixation. The first construct had a vertical figure-of-8 with one twist of wire. The second contained a vertical figure-of-8 with two twists of wire. The third was a vertical figure-of-8 with two twists of wire placed at adjacent corners while the last one had a horizontal figure-of-8 with two twists of wire placed at adjacent corners. Interfragmentary compression at the point of wire breakage was measured for each construct as well as permanent displacement on cyclic loading. Results: Placement of the figure-of-eight in a horizontal orientation with two wire twists at the corner improved interfragmentary compression by 63% (p < 0.05, Tukey post hoc test). On cyclic loading, all the constructs with vertical figure-of-eight but none with a horizontal construct failed (p = 0.01; Fisher's exact test). Permanent fracture displacement after cyclic loading was 67% lower with horizontal figure-of-eight constructs (p < 0.05; t test). Conclusion: Placing wire twists at the corner and a horizontal placement of figure-of-8 improves stability of the construct. (C) 2016 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 20 条
[1]  
Benjamin J, 1987, J Orthop Trauma, V1, P219, DOI 10.1097/00005131-198701030-00004
[2]   Biomechanical evaluation of current patella fracture fixation techniques [J].
Carpenter, JE ;
Kasman, RA ;
Patel, N ;
Lee, ML ;
Goldstein, SA .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (05) :351-356
[3]   Comparison of biodegradable and metallic tension-band fixation for patella fractures - 38 patients followed for 2 years [J].
Chen, AM ;
Hou, CL ;
Bao, JL ;
Guo, SH .
ACTA ORTHOPAEDICA SCANDINAVICA, 1998, 69 (01) :39-42
[4]  
Egol Kenneth, 2014, Iowa Orthop J, V34, P63
[5]   Clinical experience of patellar fracture fixation using metal wire or non-absorbable polyester - a study of 37 cases [J].
Gosal, HS ;
Singh, P ;
Field, RE .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 (02) :129-135
[6]  
GUADAGNI JR, 1986, CLIN ORTHOP RELAT R, P176
[7]  
Hung L K, 1993, J Orthop Trauma, V7, P252, DOI 10.1097/00005131-199306000-00010
[8]   FRACTURED PATELLA - OPERATIVE TREATMENT USING THE TENSION BAND PRINCIPLE [J].
HUNG, LK ;
CHAN, KM ;
CHOW, YN ;
LEUNG, PC .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1985, 16 (05) :343-347
[9]   Tension-band wiring of transverse fractures of patella. The effect of site of wire twists and orientation of stainless steel wire loop: a biomechanical investigation [J].
John, J. ;
Wagner, W. W. ;
Kuiper, J. H. .
INTERNATIONAL ORTHOPAEDICS, 2007, 31 (05) :703-707
[10]   Functional Outcomes After Operatively Treated Patella Fractures [J].
LeBrun, Christopher T. ;
Langford, Joshua R. ;
Sagi, H. Claude .