TESTING SYSTEM FOR DETERMINING THE MECHANICAL-BEHAVIOR OF EARLY AGE CONCRETE UNDER RESTRAINED AND FREE UNIAXIAL SHRINKAGE

被引:180
作者
KOVLER, K
机构
[1] National Building Research Institute, Technion-Israel Institute of Technology, Technion City, Haifa
来源
MATERIALS AND STRUCTURES | 1994年 / 27卷 / 170期
关键词
D O I
10.1007/BF02473424
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A modified uniaxial restrained shrinkage test was developed, characterized by complete automation and high accuracy of measurements. The system developed was such that tensile stresses remained constant throughout the cross-section, excluding any premature failure of specimen. This testing arrangement enables separation of creep strain from shrinkage by means of simultaneous testing of twin specimens, one under restrained shrinkage, and the other under free shrinkage. A variety of mechanical characteristics of the concrete (individual components of strain, shrinkage stresses, moduli of elasticity, creep coefficient and tensile strength) may be determined in one test. Results using this testing arrangement are presented for concrete cured in sealed conditions for 1 day and then exposed to drying at 30-degrees-C/40% RH.
引用
收藏
页码:324 / 330
页数:7
相关论文
共 16 条
[1]  
ALEXANDROVSKY SV, 1966, ANAL CONCRETE REINFO
[2]  
Bazant ZP, 1972, ACI J P, V69, P212
[3]  
BLOOM R, 1993, JUN P S UT HIGH STRE, V2, P1007
[4]  
Gilbert RI, 1988, TIME EFFECTS CONCRET, V1st
[5]   MODEL TO PREDICT CRACKING IN FIBER REINFORCED-CONCRETE DUE TO RESTRAINED SHRINKAGE [J].
GRZYBOWSKI, M ;
SHAH, SP .
MAGAZINE OF CONCRETE RESEARCH, 1989, 41 (148) :125-135
[6]  
KASAI Y, 1972, 1971 P INT C MECH BE, V4, P288
[7]  
KASAI Y, 1968, 22ND GEN M CEM ASS J, P172
[8]  
KOVLER K, 1992, RILEM P, V17, P91
[9]  
Kraai P. J., 1985, CONCRETE CONSTR, V30, P775
[10]  
ONG KCG, 1989, FIBER REINFORCED CEM, P179