Reducing the measuring times of a leak detector

被引:0
作者
Konwitschny, Rudolf [1 ]
机构
[1] Pfeiffer Vacuum GmbH, Berliner Str 43, D-35614 Asslar, Germany
关键词
D O I
10.1002/vipr.201600625
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
With individual as well as routine helium leak detection tests, rapid response times and fast signal decay times are of great interest for the quick and distinct localization of leaks. The effects of additional pumps connected in different setups to the recipient are described by means of a real test assembly. The operation of a high-vacuum pump series connected with the leak detection unit is presented as method of choice for reducing the response time during leak detection.
引用
收藏
页码:18 / 20
页数:3
相关论文
共 2 条
[1]  
Barfuss H., 2013, VAKUUM FORSCHUNG PRA, V25, P44
[2]   Helium test leaks [J].
Jitschin, Wolfgang ;
Farangis, Baker .
VAKUUM IN FORSCHUNG UND PRAXIS, 2014, 26 (04) :24-29