ACTIVATED PARTIAL THROMBOPLASTIN TIME REAGENTS - AN EVALUATION

被引:0
作者
HOWARTH, S
机构
关键词
ACTIVATED PARTIAL THROMBOPLASTIN TIME; AUTOMATION; COAGULATION;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Nine automated, activated partial thromboplastin time (APTT) reagents were evaluated on an automated coagulometer, in comparison with a manual reagent. The study consisted of three separate stages: 1) to choose a reagent that had a working stability between 4-degrees-C and 8-degrees-C for seven days and heparin sensitivity between 0 and 0.8 iu/ml; ii) assessment of sensitivity to specific factor deficiencies, particularly factors VIII, IX, XI and XII using standardised plasma serially diluted with factor-deficient plasma; and iii) assessment of sensitivity to the presence of a lupus anticoagulant, from a known positive panel. Only one reagent fulfilled all the essential criteria as an acceptable replacement for the manual reagent.
引用
收藏
页码:109 / 113
页数:5
相关论文
共 50 条
  • [1] Comparative analysis on characteristics of two activated partial thromboplastin time reagents
    Yasui, Yutaro
    Ishii, Toshiaki
    Tatebe, Junko
    Morita, Toshisuke
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (09)
  • [2] Lupus Anticoagulant: Sensitivity of 19 commercial activated partial thromboplastin time reagents
    Alejandro Detarsio, German
    Soler, Cristina
    Paredes, Josefina
    Cristina Milani, Angela
    Ordi-Ros, Jose
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2007, 41 (04): : 533 - 539
  • [3] Effect of argatroban on the activated partial thromboplastin time: a comparison of 21 commercial reagents
    Francis, JL
    Hursting, MJ
    BLOOD COAGULATION & FIBRINOLYSIS, 2005, 16 (04) : 251 - 257
  • [4] Effect of dermatan sulphate on activated partial thromboplastin time determined with different reagents
    Iorio, A
    Nucciarelli, F
    Renga, C
    Nenci, GG
    Gianese, F
    Agnelli, G
    HAEMOSTASIS, 1997, 27 (02) : 85 - 90
  • [5] ACTIVATED PARTIAL THROMBOPLASTIN TIME FOR AUTOMATED TECHNIQUES - A COMPARISON OF 2 COMMONLY USED REAGENTS
    CRAIG, S
    STEVENSON, KJ
    TABERNER, DA
    BRITISH JOURNAL OF BIOMEDICAL SCIENCE, 1994, 51 (04) : 321 - 327
  • [6] Shortened activated partial thromboplastin time: causes and management
    Lippi, Giuseppe
    Salvagno, Gian Luca
    Ippolito, Luigi
    Franchini, Massimo
    Favaloro, Emmanuel J.
    BLOOD COAGULATION & FIBRINOLYSIS, 2010, 21 (05) : 459 - 463
  • [7] Evaluation of the activated partial thromboplastin time (APTT) sensitivity to heparin using five commercial reagents: Implications for therapeutic monitoring
    Manzato, F
    Mengoni, A
    Grilenzoni, A
    Lippi, G
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (12) : 975 - 980
  • [8] ARACHNASE - AN EVALUATION OF A POSITIVE CONTROL FOR PLATELET NEUTRALIZATION PROCEDURE TESTING WITH 7 COMMERCIAL ACTIVATED PARTIAL THROMBOPLASTIN TIME REAGENTS
    MCGLASSON, DL
    BABCOCK, JL
    BERG, L
    TRIPLETT, DA
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 100 (05) : 576 - 578
  • [9] In vitro sensitivity of different activated partial thromboplastin time reagents to mild clotting factor deficiencies
    Toulon, P.
    Eloit, Y.
    Smahi, M.
    Sigaud, C.
    Jambou, D.
    Fischer, F.
    Appert-Flory, A.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 (04) : 389 - 396
  • [10] Differences in the Composition of Activated Partial Thromboplastin Time (APTT) Reagents Affect Clot Waveform Analysis
    Kato, Konami
    Hatayama, Yuki
    Shimohiro, Hisashi
    Ichikawa, Hitomi
    Fukuda, Tetsuya
    YONAGO ACTA MEDICA, 2022, 65 (03) : 226 - 230