Effect of Two Different Disinfectants on Dimensional Stability of Newer Alginate Impression Materials Over Five Days

被引:0
作者
Ambrose, Prem Kumar
Juszczyk, Andrzej S.
Clark, Robert K. F.
Radford, David R.
机构
关键词
Impression; Stability; Disinfectant;
D O I
10.1922/957-Clark04
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The effect of two different disinfectants on the dimensional stability of two alginate impression materials over five days was investigated. 60 impressions were made under standardised conditions, 30 with each alginate, of which ten were disinfected in each disinfectant and ten were controls. Impressions were stored over a period of five days in a container with 100% humidity. Measurements were made between four points. Two-way analysis of variance indicated no differences in the change from baseline to day 5 between any of the combinations of alginate and disinfectant. Only two of the changes between baseline and day 5 reached statistical significance at the p<0.01 level. Therefore it can be concluded that within the limitations of this study when newer alginate impression materials are disinfected they remain stable over 5 days.
引用
收藏
页码:142 / 145
页数:4
相关论文
共 11 条
[1]   BONDING PROPERTIES AND DIMENSIONAL STABILITY OF HYDROCOLLOID IMPRESSION SYSTEMS IN FIXED PROSTHODONTICS [J].
DAHL, BL ;
DYMBE, B ;
VALDERHAUG, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (06) :796-800
[2]   Accuracy of irreversible hydrocolloids (alginates) for fixed prosthodontics -: A comparison between irreversible hydrocolloid, reversible hydrocolloid, and addition silicone for use in the syringe-tray technique [J].
Eriksson, A ;
Öckert-Eriksson, G ;
Lockowandt, P .
EUROPEAN JOURNAL OF ORAL SCIENCES, 1998, 106 (02) :651-660
[3]  
Juszczyk A. S, 1995, LAB STUDY FIT CAST C, V18, P133
[4]   Accuracy and stability of impression materials subjected to chemical disinfection - a literature review [J].
Kotsiomiti, E. ;
Tzialla, A. ;
Hatjivasiliou, K. .
JOURNAL OF ORAL REHABILITATION, 2008, 35 (04) :291-299
[5]   The dimensional stability of dental impression materials following immersion in disinfecting solutions [J].
Martin, N. ;
Martin, M. V. ;
Jedynakiewicz, N. M. .
DENTAL MATERIALS, 2007, 23 (06) :760-768
[6]  
McCabe J.F., 2008, APPL DENT MAT
[7]   A STUDY OF THE CLINICAL FIT OF CAST COBALT CHROMIUM CLASPS [J].
MURRAY, MD ;
DYSON, JE .
JOURNAL OF DENTISTRY, 1988, 16 (03) :135-139
[8]  
OBRIEN WJ, 2002, DENT MAT THEIR SELEC, P90
[9]  
Sedda Maurizio, 2008, J Contemp Dent Pract, V9, P59
[10]   LINEAR-DISTORTION AND COMPATIBILITY OF AN ANTIMICROBIAL IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIAL AND IMPROVED DENTAL STONES [J].
SEVEDGE, SR ;
GUNDERSON, RB ;
SINGER, MT .
JOURNAL OF PROSTHETIC DENTISTRY, 1989, 62 (05) :612-615