SEVERE FRACTURES OF THE DISTAL RADIUS - EFFECT OF AMOUNT AND DURATION OF EXTERNAL FIXATOR DISTRACTION ON OUTCOME

被引:76
作者
KAEMPFFE, FA [1 ]
WHEELER, DR [1 ]
PEIMER, CA [1 ]
HVISDAK, KS [1 ]
CERAVOLO, J [1 ]
SENALL, J [1 ]
机构
[1] SUNY BUFFALO,SCH MED & BIOMED SCI,HAND CTR WESTERN NEW YORK,DEPT ORTHOPAED SURG,BUFFALO,NY 14260
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1993年 / 18A卷 / 01期
关键词
D O I
10.1016/0363-5023(93)90241-T
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although severe intra-articular fractures of the distal radius are often treated with external fixation/distraction, little attention has been devoted to the amount and duration of fixator distraction required to maximize outcome. To determine these effects, we conducted a retrospective study of 26 patients whose primary treatment was external fixation/distraction. Patients were evaluated by chart review, questionnaire, x-ray films, and physical examination an average of 104 weeks after injury. The carpal height index was used to quantify distraction. Scores for pain, function, wrist motion, and grip strength and the total score were adversely affected in proportion to the increase in carpal height index by distraction. Outcome was adversely affected as the duration of distraction increased. Motion scores were affected most. Overall, patients recovered at least 75% of motion and grip strength, and 85% attained New York Orthopedic Hospital grades of good or excellent. These are the first data to show that there are potential adverse effects from increasing amounts of distraction and prolonged use of the external fixator.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 37 条
[1]  
Colles, On the fracture of the carpal extremity of the radius, Edinburgh Med Surg J, 10, pp. 182-186, (1814)
[2]  
Barnett, Displaced intraarticular fractures of the distal radius, Clin Orthop, 214, pp. 148-152, (1987)
[3]  
Cooney, External fixation of distal radius fractures, Clin Orthop, 180, pp. 44-49, (1983)
[4]  
Kaukonen, Karaharju, Luthje, Porras, External fixation of Colles' fractures, Acta Orthop Scand, 60, pp. 54-56, (1989)
[5]  
Cronier, Talha, Toulemonde, Jaeger, Guntz, Resultats de la distraction par fixatuer externe metacarporadial dans les fractures de l'extremite distale du radius, J Chir (Paris), 128, pp. 8-12, (1991)
[6]  
Frykman, Fractures of the distal radius including sequelae: shoulder-hand-finger syndrome, disturbance of the distal radioulnar joint and impairment of nerve function, Acta Orthop Scand Suppl, 108, pp. 118-128, (1967)
[7]  
Vanderlinden, Ericson, Colles' fracture: how should its displacement be measured and how should it be immobilized?, J Bone Joint Surg, 63 A, pp. 1285-1288, (1981)
[8]  
Youm, McMurty, Flatt, Gillespie, Kinematics of the wrist, J Bone Joint Surg, 60 A, pp. 423-431, (1978)
[9]  
Watson, Carlson, Treatment of reflex sympathetic dystrophy of the hand with an active “stress loading” program, J Hand Surg, 12 A, pp. 779-785, (1987)
[10]  
Brady, Double pin fixation of severely comminuted fractures of the distal radius and ulna, South Med J, 56, pp. 307-311, (1963)