EFFUSION COOLING - THE INFLUENCE OF THE NUMBER OF HOLES

被引:17
作者
ANDREWS, GE
ASERE, AA
GUPTA, ML
MKPADI, MC
机构
[1] Department of Fuel and Energy, University of Leeds
关键词
D O I
10.1243/PIME_PROC_1990_204_024_02
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental measurements of the overall cooling effectiveness for full-coverage discrete hole effusion cooling are presented for a wide range of practical geometries and for a density ratio between the coolant and combustion gases of 2.5. The influence of the number of holes per unit surface area was investigated at two fixed total hole areas or design pressure loss. These were a pressure loss of 3 and 0.1 per cent for a relatively low coolant flowrate per unit surface area. Hole configurations suitable for combustor wall cooling were investigated with hole sizes from 1.4 to 0.6 mm at 3 per cent design pressure loss and 1.3 to 3.3 mm at 0.1 per cent design pressure loss. Increasing the number of holes and increasing the hole diameter were shown to increase the cooling effectiveness through improved film cooling. Major reductions in current combustor wall cooling flows were demonstrated for some full-coverage effusion geometries. © 1990, Institution of Mechanical Engineers. All rights reserved.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 21 条
  • [1] Metzger, Takeuchi, Kyenstler, Effectiveness and heat transfer with full coverage film cooling, Trans. ASME, J. Engny Power, 95, (1973)
  • [2] Brocq P.V., Saunder, Priddin, Discrete hole injection as a means of transpiration cooling, Proc. Instn Mech. Engrs, 187, (1973)
  • [3] Mayle, Camarata, Multihole cooling film effectiveness and heat transfer, Trans. ASME, J. Heat Transfer, 97, pp. 534-538, (1975)
  • [4] Sasaki M., Takahama K., Kumagai T., Hamano M., Film cooling effectiveness for injection from multirow holes, Trans. ASME., J. Engng Power, 101, pp. 101-108, (1981)
  • [5] Andrews, Alikhanizadeh M., Asere, Hussain, Khoskbar M.S., Azari, Mkpadi, Small diameter film cooling holes: Wall convective heat transfer, Trans. ASME. J. Turbomachinery, 108, pp. 283-289, (1986)
  • [6] Andrews, Alikhanizadeh M., Bazdidi F., Tehrani, Hussain, Azari, Koshkbar M.S., Small diameter film cooling holes: the influence of hole size and pitch, (1987)
  • [7] Andrews, Tehrani, Bazdidi F., Small diameter film cooling hole heat transfer: the influence of the number of holes, (1989)
  • [8] Andrews, Asere, Transpiration cooling of gas turbine combustion chamber walls, 2, pp. 1047-1056, (1984)
  • [9] Andrews, Asere A., Mkpadi, Tirmahi A., Transpiration cooling: contribution of the film cooling to the overall cooling effectiveness, pp. 245-256, (1986)
  • [10] Andrews, Gupta, Mkpadi, Full coverage discrete hole wall cooling: Cooling effectiveness. 1985, Int. J. Turbo Jet Engines, 2, pp. 199-212, (1985)