DYNAMIC EXTERNAL FIXATION OF UNSTABLE FRACTURES OF THE DISTAL PART OF THE RADIUS - A PROSPECTIVE, RANDOMIZED COMPARISON WITH STATIC EXTERNAL FIXATION

被引:82
作者
SOMMERKAMP, TG
SEEMAN, M
SILLIMAN, J
JONES, A
PATTERSON, S
WALKER, J
SEMMLER, M
BROWNE, R
EZAKI, M
机构
[1] UNIV TEXAS,DALLAS PARKLAND MEM HOSP,SW MED CTR,DEPT ORTHOPAED SURG,HAND SURG SERV,DALLAS,TX 75219
[2] TEXAS SCOTTISH RITE HOSP CHILDREN,DALLAS,TX 75219
关键词
D O I
10.2106/00004623-199408000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective, randomized study was done to compare the results of dynamic external fixation (the Clyburn device) with those of static external fixation (the AO/ASIF device) in the treatment of fifty unstable fractures of the distal part of the radius. Mobilization of the wrist from neutral to 30 degrees of flexion was begun in the dynamic-fixator group at approximately two weeks, and full motion, allowing 30 degrees of extension, was started at approximately four weeks. The external fixation frames in both groups were, kept in place for approximately ten weeks. Mobilization of the wrist in the dynamic-fixator group provided little gain in the mean motion of the wrist at the time of the removal of the fixator or at the one, six, or twelve-month evaluation. The static-fixator group had greater flexion of the wrist and radial deviation at the early and late follow-up examinations, while the dynamic-fixator group demonstrated only greater ulnar deviation one month after the fixator had been removed. Notion of the wrist in the dynamic-fixator group resulted in a statistically significant loss of radial length compared with that in the static-fixator group (four millimeters compared with one millimeter, p < 0.001). Complications were more frequent in the dynamic-fixator group. As evaluated with a modification of the scoring system of Gartland and Werley, 92 per cent of the results at one year were excellent or good in the static-fixator group and 76 per cent, in the dynamic fixator group. The results of this study cannot support the concept of early mobilization with a dynamic external fixator for the treatment of unstable fractures of the distal part of the radius.
引用
收藏
页码:1149 / 1161
页数:13
相关论文
共 48 条
[1]  
Allgower, 1979, MANUAL INTERNAL FIXA
[2]  
ALTISSIMI M, 1986, CLIN ORTHOPAEDICS, V206, P202
[3]  
ANDERSON R, 1944, SURG GYNECOL OBSTET, V78, P434
[4]   LIMITED OPEN REDUCTION OF THE LUNATE FACET IN COMMINUTED INTRA-ARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, T ;
GREEN, J ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (03) :372-377
[5]   COLLES FRACTURE - A STUDY OF 2000 CASES FROM THE NEW YORK STATE WORKMENS COMPENSATION BOARD [J].
BACORN, RW ;
KURTZKE, JF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1953, 35-A (03) :643-658
[6]  
Bassett RL, 1987, CLIN ORTHOP RELAT R, V214, P148
[7]   OPEN REDUCTION AND INTERNAL-FIXATION OF DISPLACED, COMMINUTED INTRA-ARTICULAR FRACTURES OF THE DISTAL END OF THE RADIUS [J].
BRADWAY, JK ;
AMADIO, PC ;
COONEY, WP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (06) :839-847
[8]   DYNAMIC EXTERNAL FIXATION FOR COMMINUTED INTRAARTICULAR FRACTURES OF THE DISTAL END OF THE RADIUS [J].
CLYBURN, TA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (02) :248-254
[9]   COMMINUTED FRACTURES OF DISTAL END OF RADIUS TREATED BY SKELETAL TRANSFIXION IN PLASTER CAST [J].
COLE, JM ;
OBLETZ, BE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1966, A 48 (05) :931-&
[10]  
Colles A, 1814, Edinb Med Surg J, V10, P182