A NEW OPTICAL-SYSTEM FOR THE DETERMINATION OF DEFORMATIONS AND STRAINS - CALIBRATION CHARACTERISTICS AND EXPERIMENTAL RESULTS

被引:69
作者
DERWIN, KA
SOSLOWSKY, LJ
GREEN, WDK
ELDER, SH
机构
[1] UNIV MICHIGAN, ORTHOPAED RES LABS, ANN ARBOR, MI 48109 USA
[2] UNIV MICHIGAN, CTR HUMAN GROWTH & DEV, ANN ARBOR, MI 48109 USA
关键词
D O I
10.1016/0021-9290(94)90281-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Many types of optical strain measurement systems have been used for the determination of deformations and strains in soft biological tissues. The purpose of this investigation is to report a new optical strain measurement system developed in our laboratory which offers distinct advantages over systems developed in the past. Our optical strain system has demonstrated excellent performance in calibration and experimental tests. Calibration tests illustrate the system's accuracy to 0.05% strain at 3.52% strain and 0.18% strain at 11.74% strain. Further, this system can measure strains to within 2% measurement error for strains in a 0-11.74% range when 100 mu m increments of motion are used for calibration. The resolution of our system appears to be at least as good as the linear micrometer (2 mu m) used as a calibrating standard. Errors in strain measurement due to whole specimen rotation or translation are quantified. Rotations about an in-plane axis perpendicular to the direction of strain and translations in/out of the plane of focus result in the largest sources of error. Finally, in an in vitro biomechanical study of the rabbit Achilles tendon, experimental failure strains are 4.3 +/- 0.9% using this system.
引用
收藏
页码:1277 / +
页数:1
相关论文
共 23 条
[1]   BIOCHEMICALLY DISCRETE ZONES OF CANINE FLEXOR TENDON - EVALUATION OF PROPERTIES WITH A NEW PHOTOGRAPHIC METHOD [J].
AMADIO, PC ;
BERGLUND, LJ ;
AN, KN .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (02) :198-204
[2]   STRAIN-MEASUREMENT IN THE MEDIAL COLLATERAL LIGAMENT OF THE HUMAN KNEE - AN AUTOPSY STUDY [J].
ARMS, S ;
BOYLE, J ;
JOHNSON, R ;
POPE, M .
JOURNAL OF BIOMECHANICS, 1983, 16 (07) :491-496
[3]   EFFECTS OF STRUCTURE AND STRAIN-MEASUREMENT TECHNIQUE ON THE MATERIAL PROPERTIES OF YOUNG HUMAN TENDONS AND FASCIA [J].
BUTLER, DL ;
GROOD, ES ;
NOYES, FR ;
ZERNICKE, RF ;
BRACKETT, K .
JOURNAL OF BIOMECHANICS, 1984, 17 (08) :579-596
[4]   SURFACE STRAIN VARIATION IN HUMAN PATELLAR TENDON AND KNEE CRUCIATE LIGAMENTS [J].
BUTLER, DL ;
SHEH, MY ;
STOUFFER, DC ;
SAMARANAYAKE, VA ;
LEVY, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1990, 112 (01) :38-45
[5]   LIGAMENT STRAIN IN HUMAN KNEE JOINT [J].
EDWARDS, RG ;
LAFFERTY, JF ;
LANGE, KO .
JOURNAL OF BASIC ENGINEERING, 1970, 92 (01) :131-&
[6]   ON-LINE MEASUREMENT OF MICROVASCULAR DIMENSIONS BY TELEVISION MICROSCOPY [J].
INTAGLIETTA, M ;
TOMPKINS, WR .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 32 (04) :546-+
[7]  
KENNEDY JC, CLIN ORTHOP RELAT R, V129, P225
[8]   CALIBRATION CHARACTERISTICS OF A VIDEO DIMENSION ANALYZER (VDA) SYSTEM [J].
LAM, TC ;
FRANK, CB ;
SHRIVE, NG .
JOURNAL OF BIOMECHANICS, 1992, 25 (10) :1227-1231
[9]   2-DIMENSIONAL MECHANICAL-PROPERTIES OF RABBIT SKIN .1. EXPERIMENTAL SYSTEM [J].
LANIR, Y ;
FUNG, YC .
JOURNAL OF BIOMECHANICS, 1974, 7 (01) :29-34
[10]  
Lee T. Q., 1992, ADV BIOENG, V22, P87