APPLICATION OF SELECTIVITY TUNING IN SERIES-COUPLED CAPILLARY GC COLUMNS FOR THE EXACT QUANTIFICATION OF THE QUENCHING EFFECT IN FPD DETECTION

被引:7
作者
EFER, J
MAURER, T
ENGEWALD, W
机构
[1] COMBINE CHEM PLANT CONSTRUCT LEIPZIG GRIMMA,COAL ANAL CENT LAB,O-7010 LEIPZIG,GERMANY
[2] KARL MARX UNIV,DEPT CHEM,O-7010 LEIPZIG,GERMANY
关键词
FPD-Detection; Gas chromatography; Quenching effects; Series-coupled columns; Sulfur compounds;
D O I
10.1007/BF02268695
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In a series-coupled system of two capillary columns with different polarity, a controlled overlapping of sulphur-containing and sulphur-free compounds can be achieved by means of different mid-point pressure settings. By means of this selectivity tuning it is possible to measure exactly the quenching of the flame photometric detector signal for a sulphur compound coeluted with an excess of a sulphur-free compound. With the example of a complex sample it is shown that, with a suitable system of columns, selectivity tuning can give quench-free FPD chromatograms or chromatograms with quench-free regions. © 1990 Friedr. Vieweg & Sohn Verlagsgesellschaft mbH.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 21 条
[1]   PHOTOMETRIC TIN DETECTOR FOR GAS-CHROMATOGRAPHY [J].
AUE, WA ;
FLINN, CG .
JOURNAL OF CHROMATOGRAPHY, 1977, 142 (NOV) :145-154
[2]   GAS-CHROMATOGRAPHIC SEPARATION OF SOME SULFUR-COMPOUNDS ON GLASS CAPILLARY COLUMNS USING FLAME PHOTOMETRIC DETECTION [J].
BLOMBERG, L .
JOURNAL OF CHROMATOGRAPHY, 1976, 125 (02) :389-397
[3]   DETERMINATION OF SULFUR COMPOUND DISTRIBUTION IN PETROLEUM BY GAS-CHROMATOGRAPHY WITH A FLAME PHOTOMETRIC DETECTOR [J].
BRADLEY, C ;
SCHILLER, DJ .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :3017-3021
[4]   HYDROCARBON AND WATER QUENCHING OF THE FLAME PHOTOMETRIC DETECTOR RESPONSE [J].
DRESSLER, M .
JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV) :145-150
[5]   SULFUR DETECTION IN HYDROCARBON MATRICES - A COMPARISON OF THE FLAME PHOTOMETRIC DETECTOR AND THE 700A-HALL ELECTROLYTIC CONDUCTIVITY DETECTOR [J].
EHRLICH, BJ ;
HALL, RC ;
ANDERSON, RJ ;
COX, HG .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1981, 19 (05) :245-249
[6]   SULFUR-SELECTIVE DETECTION WITH THE FPD - CURRENT ENIGMAS, PRACTICAL USAGE, AND FUTURE-DIRECTIONS [J].
FARWELL, SO ;
BARINAGA, CJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (11) :483-494
[7]   CRITICAL-APPRAISAL OF THE FLAME PHOTOMETRIC DETECTOR IN PETROLEUM ANALYSIS [J].
FERGUSON, DA ;
LUKE, LA .
CHROMATOGRAPHIA, 1979, 12 (04) :197-203
[8]   EFFECT OF CARRIER GAS-FLOW GEOMETRY ON THE RESPONSE OF SULFUR FLAME PHOTOMETRIC DETECTORS FOR GAS-CHROMATOGRAPHY [J].
FREDRIKSSON, SA ;
CEDERGREN, A .
ANALYTICAL CHEMISTRY, 1981, 53 (04) :614-618
[9]   SELECTIVITY TUNING OF SERIALLY CONNECTED OPEN-TUBULAR (CAPILLARY) COLUMNS IN GAS-CHROMATOGRAPHY .1. FUNDAMENTAL RELATIONSHIPS [J].
HINSHAW, JV ;
ETTRE, LS .
CHROMATOGRAPHIA, 1986, 21 (10) :561-572
[10]   SELECTIVITY TUNING OF SERIALLY CONNECTED OPEN-TUBULAR (CAPILLARY) COLUMNS IN GAS-CHROMATOGRAPHY .2. IMPLEMENTATION [J].
HINSHAW, JV ;
ETTRE, LS .
CHROMATOGRAPHIA, 1986, 21 (12) :669-680