REPRODUCIBILITY OF FIELD ALIGNMENT IN DIFFICULT PATIENT POSITIONING

被引:17
作者
KORTMANN, RD [1 ]
HESS, CF [1 ]
JANY, R [1 ]
MEISNER, C [1 ]
BAMBERG, M [1 ]
机构
[1] UNIV TUBINGEN, INST MED INFORMAT PROC, D-72076 TUBINGEN, GERMANY
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1994年 / 29卷 / 04期
关键词
RADIATION THERAPY; QUALITY ASSURANCE; VERIFICATION FILMS; PATIENT POSITIONING;
D O I
10.1016/0360-3016(94)90578-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Quantitative assessment of the accuracy of field alignment in a homogeneous group of patients with difficult positioning (postoperative irradiation after total hip replacement). Methods and Materials: In 95 patients linear and rotational discrepancies were measured between the simulation and first check him and between five consecutive verification films. Results: For the total group of patients, all deviations were normally distributed with mean values of approximately zero and standard deviations of 4.0-8.0 mm (linear discrepancies) and 3.5-5 degrees (rotational discrepancies). Deviations were similar for the transition from simulator to the treatment machine and for subsequent treatment delivery, with 50% and 95% of absolute differences being less than 5 mm and 15 mm, respectively. Conclusions: Our analysis indicates that statistical fluctuations are considerably more important than errors introduced at start of treatment. Therefore, a first check film seems to be inadequate to predict the expected inaccuracies for the whole course of treatment. In addition, our results should help to prescribe appropriate safety margins for patients with difficult positioning.
引用
收藏
页码:869 / 872
页数:4
相关论文
共 17 条
[1]   QUALITY ASSURANCE IN RADIATION-THERAPY - SYSTEMATIC EVALUATION OF ERRORS DURING THE TREATMENT EXECUTION [J].
BLANCO, S ;
LOPEZBOTE, MA ;
DESCO, M .
RADIOTHERAPY AND ONCOLOGY, 1987, 8 (03) :253-261
[2]   WEEKLY LOCALIZATION FILMS AND DETECTION OF FIELD PLACEMENT ERRORS [J].
BYHARDT, RW ;
COX, JD ;
HORNBURG, A ;
LIERMANN, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (9-10) :881-887
[3]   QUALITY-CONTROL AT THE PATIENT LEVEL - ACTION OR RETROSPECTIVE INTROSPECTION [J].
DUTREIX, A ;
VANDERSCHUEREN, E ;
LEUNENS, L .
RADIOTHERAPY AND ONCOLOGY, 1992, 25 (02) :146-147
[4]   IMMOBILIZATION ERROR - SOME THEORETICAL CONSIDERATIONS [J].
GOITEIN, M ;
BUSSE, J .
RADIOLOGY, 1975, 117 (02) :407-412
[5]   QUALITY-CONTROL IN RADIOTHERAPY - THE REDUCTION OF FIELD PLACEMENT ERRORS [J].
GRIFFITHS, SE ;
PEARCEY, RG ;
THOROGOOD, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (10) :1583-1588
[6]   ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY [J].
HUIZENGA, H ;
LEVENDAG, PC ;
DEPORRE, PMZR ;
VISSER, AG .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) :181-187
[7]   LOCALIZATION ERRORS IN MANTLE-FIELD IRRADIATION FOR HODGKINS-DISEASE [J].
HULSHOF, M ;
VANUYTSEL, L ;
VANDENBOGAERT, W ;
VANDERSCHUEREN, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 17 (03) :679-683
[8]   RANDOMIZED TRIAL COMPARING SINGLE DOSE VERSUS FRACTIONATED-IRRADIATION FOR PREVENTION OF HETEROTOPIC BONE - A PRELIMINARY-REPORT [J].
KONSKI, A ;
PELLEGRINI, V ;
POULTER, C ;
DEVANNY, J ;
ROSIER, R ;
EVARTS, CM ;
HENZLER, M ;
RUBIN, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05) :1139-1142
[9]   DETECTION OF SYSTEMATIC PATIENT SETUP ERRORS BY PORTAL FILM ANALYSIS [J].
LEBESQUE, JV ;
BEL, A ;
BIJHOLD, J ;
HART, AAM .
RADIOTHERAPY AND ONCOLOGY, 1992, 23 (03) :198-198
[10]   USEFULNESS OF POSTOPERATIVE HIP IRRADIATION IN THE PREVENTION OF HETEROTOPIC BONE-FORMATION IN A HIGH-RISK GROUP OF PATIENTS [J].
MACLENNAN, I ;
KEYS, HM ;
EVARTS, CM ;
RUBIN, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (01) :49-53