C2 Pedicle Sclerosis Grading, More Than Diameter, Predicts Surgeons' Preoperative Assessment of Safe Screw Placement: A Novel Classification System

被引:0
作者
Chiapparelli, Erika [1 ]
Okano, Ichiro [1 ]
Salzmann, Stephan N. [1 ]
Reisener, Marie-Jacqueline [1 ]
Virk, Sohrab [1 ]
Winter, Fabian [1 ]
Shue, Jennifer [1 ]
Sama, Andrew A. [1 ]
Cammisa, Frank P. [1 ]
Girardi, Federico P. [1 ]
Hughes, Alexander P. [1 ]
机构
[1] Hosp Special Surg, Spine Care Inst, 535 E 70th St, New York, NY 10021 USA
关键词
Assessment; C2; pedicle; Classification; Sclerosis; Screws; Vertebral artery; Width;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
-BACKGROUND: The preoperative assessment of C2 morphology is important for safe instrumentation. Sclerotic changes are often seen in C2 pedicles. Evaluating the diameter measurements solely might not accurately assess the safety of screw insertion. We have proposed a novel grading system of the C2 pedicle that includes sclerosis and evaluated the predictive value of this grading system with the surgeon's safety evaluation. -METHODS: We reviewed and measured the dimensional values in 220 cervical computed tomography angiograms. Additionally, we used a grading system that divides the findings into 5 grades according to the width measurement and degree of sclerosis in the C2 pedicle. Two spine surgeons independently classified the pedicles as follows: safe (minimal risk of pedicle violation), caution needed (caution to minimize pedicle violation), or dangerous (a high risk of pedicle violation). Finally, we compared the measurements and the surgeons' safety assessments. -RESULTS: A total of 411 pedicles of 203 patients (mean age, 69.5 years; 49.5% women) were included. Of the 411 C2 pedicles, 170 were classified as high risk by double dagger 1 surgeon. Between the dimensional measurements and grading system, the sclerotic grade showed the best predictive value. -CONCLUSIONS: We have introduced a novel tool to evaluate the safety of C2 pedicle screw placement. Our results suggest that our pedicle widthesclerosis grading system is reproducible and predicts the surgeon's assessment of safe screw placement better than C2 pedicle diametrical measurements alone.
引用
收藏
页码:E576 / E581
页数:6
相关论文
共 16 条
[11]   Anatomical Considerations for Subaxial (C2) Pedicle Screw Placement A Radiographic Study With Computed Tomography in 93 Patients [J].
Smith, Zachary A. ;
Bistazzoni, Simona ;
Onibokun, Adebukoa ;
Chen, Nan-Fu ;
Sassi, Marco ;
Khoo, Larry T. .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (03) :176-179
[12]   The vertebral artery and the cervical pedicle: morphometric analysis of a critical neighborhood Clinical article [J].
Tomasino, Andre ;
Parikh, Karishma ;
Koller, Heiko ;
Zink, Walter ;
Tsiouris, A. John ;
Steinberger, Jeremy ;
Haertl, Roger .
JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (01) :52-60
[13]   Vertebral artery injury in C1-2 transarticular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves [J].
Wright, NM ;
Lauryssen, C .
JOURNAL OF NEUROSURGERY, 1998, 88 (04) :634-640
[14]   MORPHOLOGY OF THE 2ND CERVICAL VERTEBRA AND THE POSTERIOR PROJECTION OF THE C2 PEDICLE AXIS [J].
XU, RM ;
NADAUD, MC ;
EBRAHEIM, NA ;
YEASTING, RA .
SPINE, 1995, 20 (03) :259-263
[15]   THE SCLEROTIC PEDICLE - HOW MANY CAUSES ARE THERE [J].
YOCHUM, TR ;
SELLERS, LT ;
OPPENHEIMER, DA ;
PETERSON, CK ;
KIRTON, CW ;
DALMAS, EC ;
ANDERSON, AL .
SKELETAL RADIOLOGY, 1990, 19 (06) :411-417
[16]   Spinal reconstruction using a cervical pedicle screw system [J].
Yoshimoto, H ;
Sato, S ;
Hyakumachi, T ;
Yanagibashi, Y ;
Masuda, T .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (431) :111-119