IN-VITRO TESTING OF DRY POWDER INHALERS

被引:20
|
作者
VANOORT, M
机构
[1] Glaxo Research Institute, Inhalation Product Development, Research Triangle Park, NC, 27709
关键词
D O I
10.1080/02786829408959754
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
There is increasing focus on the development of dry powder inhalers (DPIs) for the delivery of therapeutic entities to the lungs. In vitro testing of metered-dose inhalers (MDIs) has evolved through the years and general tests and methods have been published through USP general chapter [601], monographs, and guidelines issued by the FDA. In contrast, very few guidelines have been established for the testing of dry powder inhaler systems. In fact, these systems may prove to be more difficult to propose general tests for because they are based on different principles leading to a greater diversity in the number of types of devices and formulations in comparison to the MDIs. To form absolute standards at this stage will be difficult and this paper will present a comparison of the in vitro test methods of MDIs to some of the DPIs that are commercially available and suggests some guidelines to follow.
引用
收藏
页码:364 / 373
页数:10
相关论文
共 50 条
  • [1] In-vitro and particle image velocimetry studies of dry powder inhalers
    dos Reis, Larissa Gomes
    Chaugule, Vishal
    Fletcher, David F.
    Young, Paul M.
    Traini, Daniela
    Soria, Julio
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 592
  • [2] Towards Standardized Dissolution Techniques for In Vitro Performance Testing of Dry Powder Inhalers
    Floroiu, Andreea
    Klein, Martin
    Kraemer, Johannes
    Lehr, Claus-Michael
    DISSOLUTION TECHNOLOGIES, 2018, 25 (03): : 6 - 18
  • [3] In vitro testing of two formoterol dry powder inhalers at different flow rates
    Weuthen, T
    Roeder, S
    Brand, P
    Müllinger, B
    Scheuch, G
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2002, 15 (03): : 297 - 303
  • [4] ANALYTICAL TECHNOLOGIES FOR TESTING DRY POWDER INHALERS
    Daniels, Geoff
    Rice, Andrew
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2013, 26 (04) : A246 - A247
  • [5] FACTORS AFFECTING IN-VITRO TESTING OF INHALERS
    DICKENS, CJ
    MCAUGHEY, JJ
    KNIGHT, DA
    BAKER, ST
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1994, 7 (02): : 193 - 196
  • [6] Equivalence testing and equivalence limits of metered-dose inhalers and dry powder inhalers measured by in vitro impaction
    Weda, M
    Geuns, ERM
    Vermeer, RCR
    Buiten, NRA
    Hendriks-de Jong, K
    Bult, A
    Zanen, P
    Barends, DM
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2000, 49 (03) : 295 - 302
  • [7] Application of spectrofluorometry for evaluation of dry powder inhalers in vitro
    Srichana, T
    Suedee, R
    Srisudjai, P
    PHARMAZIE, 2003, 58 (02): : 125 - 129
  • [8] Equivalence testing of salbutamol dry powder inhalers: in vitro impaction results versus in vivo efficacy
    Weda, M
    Zanen, P
    de Boer, AH
    Gjaltema, D
    Ajaoud, A
    Barends, DM
    Frijlink, HW
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 249 (1-2) : 247 - 255
  • [9] Effects of Device and Formulation on In Vitro Performance of Dry Powder Inhalers
    Adams, Wallace P.
    Lee, Sau L.
    Plourde, Robert
    Lionberger, Robert A.
    Bertha, Craig M.
    Doub, William H.
    Bovet, Jean-Marc
    Hickey, Anthony J.
    AAPS JOURNAL, 2012, 14 (03): : 400 - 409
  • [10] Effects of Device and Formulation on In Vitro Performance of Dry Powder Inhalers
    Wallace P. Adams
    Sau L. Lee
    Robert Plourde
    Robert A. Lionberger
    Craig M. Bertha
    William H. Doub
    Jean-Marc Bovet
    Anthony J. Hickey
    The AAPS Journal, 2012, 14 : 400 - 409