AN EVALUATION OF A DIRECT METHOD OF BUBBLE-SIZE DISTRIBUTION MEASUREMENT IN A LABORATORY BATCH FLOTATION CELL

被引:64
|
作者
TUCKER, JP
DEGLON, DA
FRANZIDIS, JP
HARRIS, MC
OCONNOR, CT
机构
关键词
FLOTATION; BUBBLE SIZE; BUBBLE SAMPLER; FROTHERS;
D O I
10.1016/0892-6875(94)90098-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this paper a novel bubble sampler is described which allows the measurement of bubble size distributions in flotation cells containing slurries of high solids concentration. The device separates bubbles from a slurry into a water solution where they may be measured using a bubble size analyser. An experimental programme of measuring bubble sizes in two and three-phases is reported in which the bubble sampler was evaluated and the effect of different frothers on the bubble size distribution in two and three-phases was investigated. In two-phase operation (liquid/gas), the bubble sampler was proved to supply accurate and reproducible measurements when compared with measurements made hy the bubble size analyser without the sampler fitted. The frother type was found to have the greatest influence on bubble size. With the addition of solids (gold plant tailings) to form a three phase (solid/liquid/gas) system,the mean bubble size was found to increase, and only the further addition of frother could reduce it to its former value. Different frothers were found to have very different effects on the size of bubbles produced in slurries compared with those produced in two-phase systems. Of the frothers tested MIBC was found to be the best all round performer in terms of bubble size reduction with increasing solids concentration.
引用
收藏
页码:667 / 680
页数:14
相关论文
共 50 条
  • [1] BUBBLE-SIZE DISTRIBUTION IN A FLOTATION COLUMN
    BISWAL, SK
    REDDY, PSR
    BHAUMIK, SK
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1994, 72 (01): : 148 - 152
  • [2] ESTIMATION OF GAS HOLD-UP AND BUBBLE-SIZE IN A LABORATORY FLOTATION CELL
    KAYA, M
    LAPLANTE, AR
    CIM BULLETIN, 1987, 80 (902): : 78 - 78
  • [3] MEASUREMENT OF BUBBLE-SIZE DISTRIBUTION IN FERMENTERS
    BRENTRUP, L
    ONKEN, U
    BIOTECHNOLOGY LETTERS, 1979, 1 (10) : 427 - 432
  • [4] BUBBLE-SIZE IN FLOTATION THICKENING
    DERIJK, SE
    VANDERGRAAF, JHJM
    DENBLANKEN, JG
    WATER RESEARCH, 1994, 28 (02) : 465 - 473
  • [5] HOLDUP PROFILE AND BUBBLE-SIZE DISTRIBUTION OF FLOTATION COLUMN FROTHS
    YIANATOS, JB
    FINCH, JA
    LAPLANTE, AR
    CANADIAN METALLURGICAL QUARTERLY, 1986, 25 (01) : 23 - 29
  • [6] MEASUREMENT OF BUBBLE-SIZE DISTRIBUTION - AN ACOUSTIC TECHNIQUE
    PANDIT, AB
    VARLEY, J
    THORPE, RB
    DAVIDSON, JF
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (05) : 1079 - 1089
  • [7] ERRORS IN THE MEASUREMENT OF BUBBLE-SIZE DISTRIBUTION IN FOAM
    CHENG, HC
    LEMLICH, R
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1983, 22 (01): : 105 - 109
  • [8] ESTIMATION OF BUBBLE-SIZE IN FLOTATION COLUMNS
    ITYOKUMBUL, MT
    SALAMA, AIA
    ALTAWEEL, AM
    MINERALS ENGINEERING, 1995, 8 (1-2) : 77 - 89
  • [9] THE EFFECT OF BUBBLE-SIZE DISTRIBUTION ON SELECTIVITY OF IRON-ORE FLOTATION
    SZATKOWSKI, M
    FREYBERGER, WL
    INTERNATIONAL JOURNAL OF MINERAL PROCESSING, 1988, 23 (3-4) : 213 - 227
  • [10] ESTIMATION OF BUBBLE-SIZE DISTRIBUTION IN FLOTATION COLUMNS BY DYNAMIC BUBBLE-DISENGAGEMENT TECHNIQUE
    STANDISH, N
    YU, AB
    IGUSTINGURAH, A
    TRANSACTIONS OF THE INSTITUTION OF MINING AND METALLURGY SECTION C-MINERAL PROCESSING AND EXTRACTIVE METALLURGY, 1991, 100 : C31 - C41