Experimental study of two-way post-tensioned flat slabs in fire

被引:2
|
作者
Zhang, Li [1 ]
Wei, Ya [1 ]
Au, Francis Tat Kwong [1 ]
Li, Jing [2 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
[2] South China Univ Technol, Guangzhou, Guangdong, Peoples R China
关键词
Spalling; Structural analysis; Flat slabs; Prestressed concrete; Temperature effect;
D O I
10.1108/JSFE-01-2017-0016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Purpose This study aims to investigate the influence of tendon layout, pre-stressing force, bond condition and concrete spalling on the structural behaviour of two-way post-tensioned flat slabs at elevated temperatures. Design/methodology/approach Fire tests of four scale specimens of two-way post-tensioned concrete flat slabs were performed and analysed. Three of them were provided with bonded tendons, while the other was unbonded for comparison. The fabrication of specimens, phenomena observed during testing, temperature distributions, deflections and occurrence of concrete spalling were examined. Findings Different degrees of concrete spalling observed at the soffit had significant effects on the temperature distribution and stress redistribution. This was the major reason for the progressive concrete spalling observed, resulting in loss of structural integrity and stiffness. Originality/value The structural behaviour of two-way post-tensioned concrete flat slabs at elevated temperatures is less understood compared to their one-way counterparts. Therefore, the present study has focused on the structural behaviour of two-way post-tensioned concrete flat slabs with bonded tendons in fire, a field in which relatively little information on experimental work can be found.
引用
收藏
页码:237 / 251
页数:15
相关论文
共 50 条
  • [1] Fire Behavior of Two-Way Post-Tensioned Concrete Slabs Provided with Bonded Tendons: An Experimental Study
    Zhang, Li
    Wei, Ya
    Au, Francis Tat Kwong
    Li, Jing
    STRUCTURES IN FIRE, 2016, : 45 - 52
  • [2] Experimental and numerical investigation of post-tensioned concrete flat slabs in fire
    Wei, Ya
    Au, Francis T. K.
    Li, Jing
    Tsang, Neil C. M.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2016, 7 (01) : 2 - 18
  • [3] Analysis of Non-Prismatic Two-Way Post-Tensioned Slabs
    Wei Zhou
    KSCE Journal of Civil Engineering, 2018, 22 : 1782 - 1791
  • [4] Analysis of Non-Prismatic Two-Way Post-Tensioned Slabs
    Zhou, Wei
    KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (05) : 1782 - 1791
  • [5] Modeling of post-tensioned one-way and two-way slabs with unbonded tendons
    Kim, Uksun
    Huang, Yu
    Chakrabarti, Pinaki R.
    Kang, Thomas H-K.
    COMPUTERS AND CONCRETE, 2014, 13 (05): : 587 - 601
  • [6] A Study on a Two-Way Post-Tensioned Concrete Waffle Slab
    Moldovan, Ilinca
    Mathe, Aliz
    9TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING, INTER-ENG 2015, 2016, 22 : 227 - 234
  • [7] Finite Element Modeling of Post-Tensioned Two-Way Concrete Slabs under Flexural Loading
    Abdul-Razzaq, Khattab S.
    Mohammed, Abbas H.
    Mohammedali, Taha K.
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2018, 4 (01): : 1 - 10
  • [8] Fire tests on unbonded post-tensioned one-way concrete slabs
    Bailey, C. G.
    Ellobody, E.
    MAGAZINE OF CONCRETE RESEARCH, 2009, 61 (01) : 67 - 76
  • [9] SHEAR AND MOMENT TRANSFER IN POST-TENSIONED FLAT SLABS
    CLARK, BE
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 1-DESIGN AND CONSTRUCTION, 1979, 66 (NOV): : 679 - 687
  • [10] Fire tests on bonded post-tensioned concrete slabs
    Bailey, Colin G.
    Ellobody, Ehab
    ENGINEERING STRUCTURES, 2009, 31 (03) : 686 - 696