COMPUTER-PROGRAM FOR CONNECTION AND DATA MANAGEMENT OF AN AUTOMATED COAGULATION SYSTEM - THE KC-10

被引:0
作者
CAMBUS, JP
NGUYEN, F
DEGRAEVE, J
ARAGON, B
VALDIGUIE, P
机构
[1] CHU RANGUEIL,BIOCHIM LAB,F-31054 TOULOUSE,FRANCE
[2] UNIV TOULOUSE 3,LAMI,F-31400 TOULOUSE,FRANCE
关键词
KC; 10; AUTOMATIC TESTER; COAGULATION TESTER; MICROCOMPUTER;
D O I
10.1016/0169-2607(94)90090-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In Europe, the KC 10, manufactured by Amelung Germany, is one of the instruments most commonly found in coagulation laboratories. For facilitating the work of technical validation, we wrote a software adapted to any IBM(R) or compatible PC running under MS-DOS(R), to manage the analyser performance. Data are automatically collected via the BCD interface from the analyser or keyed in for the other techniques. The software deals with 64 different analyses entirely 'user defined'. An 'electronic worksheet' presents the results, by page of ten patients. This enables the laboratory technician to assess the coherence of the various data and to perform verifications or complementary tests if necessary. As an option, a blinking asterisk can signal all results outside predetermined range. By moving the cursor through the table, a test result can be deleted, modified or added. A function displays the patient's previous files in a window because the data are recorded in long-term archives at the end of the day. This long-term recording allows a search of previous files to decide additional tests if the patient is unknown. A daily archive function classifies and prints the whole day's work in alphabetical order. A protocol of communication allows connection to a mainframe Bayer-Technicon(R) computer. This program and the user's manual are free, available on request from address above.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 8 条
  • [1] CRESPO B, 1983, NOUV REV FR HEMATOL, V25, P113
  • [2] FORESTIER F, 1986, NOUV REV FR HEMATOL, V28, P157
  • [3] FORESTIER F, 1984, REV FR LAB, V130, P85
  • [4] THE USE OF CONTROL CHARTS IN THE CLINICAL LABORATORY
    LEVEY, S
    JENNINGS, ER
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1950, 20 (11) : 1059 - 1066
  • [5] SCHULTZ L, 1982, TECH BIOL, V8, P158
  • [6] AUTOMATION AND PROTHROMBIN TIME - A UNITED-KINGDOM FIELD-STUDY OF 2 WIDELY USED COAGULOMETERS
    THOMSON, JM
    TABERNER, DA
    POLLER, L
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1990, 43 (08) : 679 - 684
  • [7] VONCLAUSS A, 1957, ACTA HAEMAT, V17, P237
  • [8] KC 10 SERVICE INFORM