ACCURACY OF A COMPUTER-BASED ANESTHETIC AUDIT SYSTEM

被引:5
作者
LILLYWHITE, N
WARD, P
机构
[1] London, SW19 6AY, 65 Selhurst Close, Parkside
[2] London, SW19 6AY, 65 Selhurst Close, Parkside
关键词
ANESTHESIA; AUDIT;
D O I
10.1111/j.1365-2044.1993.tb07420.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The accuracy of an anaesthetic computer‐based audit system was assessed. In a retrospective survey of operations performed 4 months previously only 50% of the patients' notes could be found, and 40% of these notes did not contain an anaesthetic chart. A prospective survey was also performed. The accuracy with which the computer output reflected the anaesthetic technique was found to be 52% in the retrospective survey and 33% in the prospective survey. The authors conclude that audit systems should be audited before their generated data are used for decision‐making. Copyright © 1993, Wiley Blackwell. All rights reserved