RISK-FACTORS FOR INFUSION-RELATED PHLEBITIS WITH SMALL PERIPHERAL VENOUS CATHETERS - A RANDOMIZED CONTROLLED TRIAL

被引:350
作者
MAKI, DG [1 ]
RINGER, M [1 ]
机构
[1] UNIV WISCONSIN, SCH MED, MADISON, WI 53706 USA
关键词
D O I
10.7326/0003-4819-114-10-845
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To identify risk factors for infusion-related phlebitis with peripheral intravenous catheters. Design: A randomized trial of two catheter materials, with consideration of 21 potential risk factors. Setting: A university hospital. Patients: Hospitalized adults without granulocytopenia who received a peripheral intravenous catheter. Interventions: House officers or ward nurses inserted the catheters, and each insertion was randomized to a catheter made of tetrafluoroethylene-hexafluoropropylene (FEP-Teflon) or a novel polyetherurethane without leachable additives (PEU-Vialon). Measurements: Research nurses scored insertion sites each day for inflammation and cultured catheters at removal. Results: The Kaplan-Meier risk for phlebitis exceeded 50% by day 4 after catheterization. Intravenous antibiotics (relative risk, 2.00), female sex (relative risk, 1.88), prolonged (> 48 hours) catheterization(relative risk, 1.79), and catheter material (PEU-Vialon: FEP-Teflon) (relative risk, 0.73) strongly predicted phlebitis in a Cox proportional hazards model (each, P < 0.003). The best-fit model for severe phlebitis identified the same predictors plus catheter-related infection (relative risk, 6.19), phlebitis with a previous catheter (relative risk, 1.54), and anatomic site (hand: forearm, relative risk, 0.71; wrist:forearm, relative risk, 0.60). The low incidence of local catheter-related infection was comparable wwith the two catheter materials (5.4% [95% CI, 3.8% to 7.6%] and 6.9% [CI, 4.9% to 9.6%]); none of the 1054 catheters prospectively studied caused bacteremia. Conclusions: Multiple factors, including the infusate and the duration of cannulation, contribute to the development of infusion-related phlebitis. The use of peripheral intravenous catheters made of PEU-Vialon appears to pose the same risk for catheter-related infection as the use of catheters made of FEP-Teflon, and PEU-Vialon can permit longer cannulation with less risk for phlebitis. The risk for catheter-related bacteremia with FEP-Teflon and PEU-Vialon catheters is sufficiently low that it no longer seems justifiable to recommend the use of small steel needles for most peripheral intravenous therapy.
引用
收藏
页码:845 / 854
页数:10
相关论文
共 67 条
  • [1] ADAMS SD, 1986, HEART LUNG, V15, P134
  • [2] ASHKENAZI S, 1984, LANCET, V1, P1075
  • [3] BAPTISTA RJ, 1987, CLIN PHARMACY, V6, P314
  • [4] PREVENTION OF LIDOCAINE-INFUSION PHLEBITIS BY HEPARIN AND HYDROCORTISONE
    BASSAN, MM
    SHEIKHHAMAD, D
    [J]. CHEST, 1983, 84 (04) : 439 - 441
  • [5] BIVINS BA, 1979, SURGERY, V85, P388
  • [6] BRESLOW NE, 1988, 76 U WASH SCH PUBL H, V76, P1
  • [7] BRESLOW NE, 1980, STATISTICAL METHODS, V1, P146
  • [8] BRESLOW NE, 1987, STATISTICAL METHODS, V2, P1
  • [9] CONTAMINATION OF INTRAVENOUS-INFUSION FLUID - EFFECTS OF CHANGING ADMINISTRATION SETS
    BUXTON, AE
    HIGHSMITH, AK
    GARNER, JS
    WEST, CM
    STAMM, WE
    DIXON, RE
    MCGOWAN, JE
    [J]. ANNALS OF INTERNAL MEDICINE, 1979, 90 (05) : 764 - 768
  • [10] THE COMPLICATIONS OF INTRAVENOUS CANNULAE INCORPORATING A VALVED INJECTION SIDE PORT
    CHEESBROUGH, JS
    FINCH, RG
    MACFARLANE, JT
    [J]. JOURNAL OF HYGIENE, 1984, 93 (03) : 497 - 504