EVALUATION OF SERUM DIGOXIN AND SERUM CORTISOL BY RADIOIMMUNOASSAY WITH THE CONCEPT-4

被引:2
|
作者
WALSH, PR
ABARCA, SD
WANG, MC
机构
[1] Department of Chemistry, Laboratory. Procedures East, Inc. Subsidiary, the Upjohn Company, King of Prussia
关键词
D O I
10.1016/S0009-9120(79)80136-8
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The solid-phase radioimmunoassay procedures for serum digoxin and cortisol with the Concept-4 were evaluated for specificity, correlation with other radioimmunoassay procedures, parallelism, recovery, carryover, and precision.1.The detection limits of the digoxin and cortisol assays were 10 pg/tube and 40 pg/tube, respectively. These detections correspond to serum concentrations of 0.25 μg/liter and 20 μg/liter, respectively, for digoxin and cortisol.2.Specificity of the digoxin assay was characterized by a 18.3% cross reaction with digitoxin. The anti-cortisol with 11-deoxycortisol. cross reaction with 11-deoxycortisol.3.The values obtained with the Concept-4 for both procedures demonstrated acceptable correlations with other existing RIA procedures.4.Dilution studies conducted to determine the parallelism of the 2 assays indicated that both assays demonstrated excellent proportionality between the volume of specimen and the quantity of analyte measured.5.Analytical recoveries of digoxin and cortisol added to the individual assays average 95% and 101%, respectively.6.Carryover studies indicated a routine sample-to-sample interaction of < 0.05% for both assays.7.The digoxin assay routinely demonstrated intra- and inter-assay variations of < 7.4% and < 10.0%, respectively. The precision data for cortisol indicated intra- and inter-assay variations of < 6.7% and < 9.1%, respectively. © 1979.
引用
收藏
页码:118 / 122
页数:5
相关论文
共 50 条
  • [1] CLINICAL LABORATORY EVALUATION OF SERUM DIGOXIN AND CORTISOL BY RIA PROCEDURES ON CONCEPT-4
    WALSH, PR
    ABARCA, SD
    WANG, MC
    CLINICAL CHEMISTRY, 1978, 24 (06) : 1040 - 1040
  • [2] EVALUATION OF AN AUTOMATED RADIOIMMUNOASSAY FOR SERUM CORTISOL
    VALDES, R
    WILLS, MR
    SAVORY, J
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1980, 10 (06) : 508 - 514
  • [3] SERUM DIGOXIN BY RADIOIMMUNOASSAY
    HOESCHEN, RJ
    PROVEDA, V
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1971, 105 (02) : 170 - &
  • [4] SERUM DIGOXIN (DIG) BY RADIOIMMUNOASSAY
    SODE, J
    WALSH, FM
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1973, 59 (01) : 145 - 145
  • [5] RADIOIMMUNOASSAY OF SERUM DIGOXIN IN RELATION TO DIGOXIN INTOXICATION
    SINGH, RB
    RAI, AN
    DUBE, KP
    SRIVASTAV, DK
    SOMANI, PN
    KATIYAR, BC
    BRITISH HEART JOURNAL, 1975, 37 (06): : 619 - 623
  • [6] ANESTHETIC APPLICATION OF SERUM DIGOXIN RADIOIMMUNOASSAY
    CALVERLEY, RK
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1972, 19 (01) : 20 - +
  • [7] RADIOIMMUNOASSAY OF SERUM DIGOXIN LEVELS TECHNICAL ASPECTS
    GALLAND, F
    GALLOIS, Y
    JALLET, P
    PATHOLOGIE BIOLOGIE, 1981, 29 (08): : 486 - 490
  • [8] PROBLEMS IN AUTOMATION OF SERUM CORTISOL RADIOIMMUNOASSAY
    STALLA, G
    MULLER, OA
    WOOD, WG
    SCRIBA, PC
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1978, 290 (02): : 168 - 169
  • [9] Radioimmunoassay for cortisol in pig saliva and serum
    Cook, NJ
    Schaefer, AL
    Lepage, P
    Jones, SDM
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (02) : 395 - 399
  • [10] DETERMINATION OF SERUM-DIGOXIN CONCENTRATIONS BY RADIOIMMUNOASSAY
    LARBIG, D
    KOCHSIEK, K
    KLINISCHE WOCHENSCHRIFT, 1971, 49 (18): : 1031 - &