Transient Evoked and Distortion Product Otoacoustic Emissions in a Group of Neonates

被引:3
|
作者
Silva, Giovanna Cesar [1 ]
Delecrode, Camila Ribas [1 ]
Kemp, Adriana Tahara [1 ]
Martins, Fabiana [2 ]
Vieira Cardoso, Ana Claudia [1 ]
机构
[1] UNESP Marilia, Dept Speech Language & Hearing Therapy, Marilia, SP, Brazil
[2] Matern Gota de Leite, Dept Fonoaudiol, Marilia, SP, Brazil
关键词
audiology; neonatal screening; hearing tests;
D O I
10.1055/s-0035-1546431
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Introduction The most commonly used method in neonatal hearing screening programs is transient evoked otoacoustic emissions in the first stage of the process. There are few studies comparing transient evoked otoacoustic emissions with distortion product, but some authors have investigated the issue. Objective To correlate the results of transient evoked and distortion product otoacoustic emissions in a Brazilian maternity hospital. Methods This is a cross-sectional, comparative, and prospective study. The study included 579 newborns, ranging from 6 to 54 days of age, born in a low-risk maternity hospital and assessed for hearing loss. All neonates underwent hearing screening by transient evoked and distortion product otoacoustic emissions. The results were analyzed using the Spearman correlation test to relate the two procedures. Results The pass index on transient evoked otoacoustic emissions was 95% and on distortion product otoacoustic emissions was 91%. The comparison of the two procedures showed that 91% of neonates passed on both procedures, 4.5% passed only on transient evoked otoacoustic emissions, 0.5% passed only on distortion product otoacoustic emissions, and 4% failed on both procedures. The inferential analysis showed a significant strong positive relationship between the two procedures. Conclusion The failure rate was higher in distortion product otoacoustic emissions when compared with transient evoked; however, there was correlation between the results of the procedures.
引用
收藏
页码:255 / 258
页数:4
相关论文
共 50 条
  • [31] TEST RETEST RELIABILITY OF DISTORTION-PRODUCT AND TRANSIENTLY EVOKED OTOACOUSTIC EMISSIONS
    FRANKLIN, DJ
    MCCOY, MJ
    MARTIN, GK
    LONSBURYMARTIN, BL
    EAR AND HEARING, 1992, 13 (06): : 417 - 429
  • [32] Estimation of distortion product otoacoustic emissions
    Ma, WK
    Zhang, YT
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (10) : 1261 - 1264
  • [33] Frequency shifts in distortion-product otoacoustic emissions evoked by swept tones
    Shera, Christopher A.
    Abdala, Carolina
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2016, 140 (02): : 936 - 944
  • [34] Behaviors of cubic distortion product otoacoustic emissions evoked by amplitude modulated tones
    Bian, Lin
    Chen, Shixiong
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 129 (02): : 828 - 839
  • [35] Acoustic modulation of electrically evoked distortion product otoacoustic emissions in gerbil cochlea
    Ren, TY
    NEUROSCIENCE LETTERS, 1996, 207 (03) : 167 - 170
  • [36] DISTORTION-PRODUCT AND CLICK-EVOKED OTOACOUSTIC EMISSIONS IN HEALTHY NEWBORNS
    LAFRENIERE, D
    JUNG, MD
    SMURZYNSKI, J
    LEONARD, G
    KIM, DO
    SASEK, J
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1991, 117 (12) : 1382 - 1389
  • [37] Distortion-product and transiently evoked otoacoustic emissions - comparison of diagnostic value
    Schmuziger, N
    AKTUELLE PROBLEME DER OTORHINOLARYNGOLOGIE 21, 1998, 21 : 94 - 101
  • [38] Transient evoked otoacoustic emissions in the elderly
    Stenklev, NC
    Laukli, E
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2003, 42 (03) : 132 - 139
  • [39] DISTORTION-PRODUCT OTOACOUSTIC EMISSIONS
    SEIDMAN, MD
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1995, 112 (04) : 628 - 628
  • [40] Contralaterally evoked transient otoacoustic emissions
    Pratt, H
    Shi, YB
    Polyakov, A
    HEARING RESEARCH, 1998, 115 (1-2) : 39 - 44