DETECTION OF TNT IN WATER USING AN EVANESCENT-WAVE FIBEROPTIC BIOSENSOR

被引:129
作者
SHRIVERLAKE, LC [1 ]
BRESLIN, KA [1 ]
CHARLES, PT [1 ]
CONRAD, DW [1 ]
GOLDEN, JP [1 ]
LIGLER, FS [1 ]
机构
[1] USN,RES LAB,CTR MOLEC SCI & ENGN,WASHINGTON,DC 20375
关键词
D O I
10.1021/ac00110a018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A general health hazard from explosive toxicity exists due to poor storage facilities for explosives and from contamination of soil and water with byproducts of explosive manufacture. To provide an effective method for monitoring water contamination, the Naval Research Laboratory's fiber-optic biosensor was adapted for the detection of small molecules such as explosives. A competitive immunoassay was developed for the detection of the most widely used explosive, trinitrotoluene (TNT). Trinitrobenzenesulfonic acid (TNB), an analog of TNT, was labeled with a fluorophore and used as the analyte competitor. A solution containing 7.5 ng/mL sulfoindocyanine 5-ethylenediamine-labeled TNB (Cy5-EDA-TNB) was exposed to an antibody-coated optical fiber, generating a specific signal above background that corresponds to the 100% or reference signal. Inhibition of the 100% signal was proportional to the TNT concentration in the sample. Detection sensitivities of 10 ng/mL TNT (8 ppb) in buffer were achieved. Tests on river, harbor, and bilge water samples spiked with TNT showed results similar to tests on laboratory (buffer matrix) samples. To determine possible interferences, several structural analogs of TNT were tested.
引用
收藏
页码:2431 / 2435
页数:5
相关论文
共 17 条
[1]   DEVELOPMENT OF AN EVANESCENT-WAVE FIBER OPTIC BIOSENSOR [J].
ANDERSON, GP ;
GOLDEN, JP ;
CAO, LK ;
WIJESURIYA, D ;
SHRIVERLAKE, LC ;
LIGLER, FS .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1994, 13 (03) :358-368
[2]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[3]  
ECK DL, 1990, ACS S SERIES, V442, pCH9
[4]  
FETTEROLF DD, 1991, J FORENSIC SCI, V36, P343
[5]   FLUOROMETER AND TAPERED FIBER OPTIC PROBES FOR SENSING IN THE EVANESCENT WAVE [J].
GOLDEN, JP ;
SHRIVERLAKE, LC ;
ANDERSON, GP ;
THOMPSON, RB ;
LIGLER, FS .
OPTICAL ENGINEERING, 1992, 31 (07) :1458-1462
[6]   COMPARISON OF SOLID-PHASE EXTRACTION WITH SALTING-OUT SOLVENT-EXTRACTION FOR PRECONCENTRATION OF NITROAROMATIC AND NITRAMINE EXPLOSIVES FROM WATER [J].
JENKINS, TF ;
MIYARES, PH ;
MYERS, KF ;
MCCORMICK, EF ;
STRONG, AB .
ANALYTICA CHIMICA ACTA, 1994, 289 (01) :69-78
[7]  
JUDD LL, 1993, FIELD SCREENING METH, V2, P732
[8]  
KUSTERBECK AW, UNPUB COMMUNICATION
[9]  
LIGLER FS, 1991, Patent No. 5077210
[10]  
PUTNAM DR, 1992, NAVSEA SEA05V1 FIN T