REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF COCAINE IN PLASMA AND HUMAN HAIR WITH DIRECT FLUOROMETRIC DETECTION

被引:34
作者
TAGLIARO, F [1 ]
ANTONIOLI, C [1 ]
DEBATTISTI, Z [1 ]
GHIELMI, S [1 ]
MARIGO, M [1 ]
机构
[1] UNIV BRESCIA,SCH MED,INST CHEM,BRESCIA,ITALY
关键词
D O I
10.1016/0021-9673(94)85225-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, but sensitive and specific, high-performance liquid chromatographic assay for cocaine with direct fluorimetric detection, particularly intended for the routine analysis of hair and blood samples, is described. Benzoylecgonine, eluting before cocaine in a completely resolved peak, is also detectable. Detection is based on the weak native fluorescence of cocaine and benzoylecgonine, depending on the benzene ring present in both molecules. Hair samples (20-200 mg) were incubated overnight in 2 ml of 0.25 M HCl at 45 degrees C and extracted with a commercial liquid-liquid method; the dried residue reconstituted with 500 mu l of 0.05 M NaH2PO4 (pH 5.2) was injected. Blood plasma samples (200 mu l) were mixed with 150 mu l of 0.1 M Na2HPO4 (pH 8.9) and extracted with 5 ml of chloroform-2-propano1 (9:1); the organic phase was evaporated and the residue dissolved and injected as above. Isocratic reversed-phase liquid chromatography was carried out on a column (150 x 4.6 mm I.D.) packed with spherical 5-mu m poly(styrene-divinylbenzene) particles; the mobile phase was 0.1 M potassium phosphate (pH 3)-methanol-tetrahydrofuran (70:25:5). The excitation and emission wavelengths were set at 230 and 315 nm, respectively. Under the described conditions, cocaine eluted in a symmetrical peak with a capacity factor of about 5. The limit of detection was about 1 ng/ml (0.2 ng injected), with a signal-to-noise ratio of 3. Using external standardization and partial loop filling, the intra-assay precision of the assay was characterized by R.S.D.s of 5.0 and 3.6% (n = 6) for cocaine concentrations of 10 and 100 ng/ml, respectively, and in inter-assay tests (n = 6) R.S.D.s of 7.5 and 5.2% were achieved for the same cocaine levels. The linearity of the method was fairly good in the concentration range 1.5-500 ng/ml (r(2) = 0.9998). Possible interferences from as many as 90 therapeutic and/or illicit drugs were excluded.
引用
收藏
页码:207 / 215
页数:9
相关论文
共 38 条
[1]  
ANTA GB, 1992, COCAINE TODAY ITS EF, P144
[2]  
BASELT RC, 1982, DISPOSITION TOXIC DR, P193
[3]   DETERMINATION OF COCAINE AND NORCOCAINE IN PLASMA AND CELL-CULTURES USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BOUIS, P ;
TACCARD, G ;
BOELSTERLI, UA .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 526 (02) :447-459
[4]  
CHAN SC, 1991, CLIN CHEM, V37, P1289
[5]   RAPID ASSAY OF COCAINE, OPIATES AND METABOLITES BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CONE, EJ ;
DARWIN, WD .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 580 (1-2) :43-61
[6]   ION-TRAP MASS-SPECTROMETRY APPLICATIONS IN FORENSIC SCIENCES .1. IDENTIFICATION OF MORPHINE AND COCAINE IN HAIR EXTRACTS OF DRUG-ADDICTS [J].
CURCURUTO, O ;
GUIDUGLI, F ;
TRALDI, P ;
STURARO, A ;
TAGLIARO, F ;
MARIGO, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (07) :434-437
[7]   GAS-CHROMATOGRAPHIC DETERMINATION OF COCAINE IN WHOLE-BLOOD AND PLASMA USING A NITROGEN-SENSITIVE FLAME IONIZATION DETECTOR [J].
DVORCHIK, BH ;
MILLER, SH ;
GRAHAM, WP .
JOURNAL OF CHROMATOGRAPHY, 1977, 135 (01) :141-148
[8]   ANALYSIS OF COCAINE AND COCAINE METABOLITES BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
EVANS, MA ;
MORARITY, T .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1980, 4 (01) :19-22
[9]  
FINKLE BS, 1987, CLIN CHEM, V33, pB13
[10]   POTENTIAL ERRORS IN BENZOYLECGONINE AND COCAINE ANALYSIS [J].
FLETCHER, SM ;
HANCOCK, VS .
JOURNAL OF CHROMATOGRAPHY, 1981, 206 (01) :193-195