EARLY RESULTS OF CRYOPRESERVED PULMONARY ALLOGRAFTS AS AORTIC-VALVE SUBSTITUTE

被引:9
作者
MAIR, R
HARRINGER, W
GROSS, C
HARTL, P
WIMMERGREINECKER, G
BRUCKE, P
机构
[1] Department of Surgery, General Hospital Linz, Linz
关键词
ALLOGRAFT; PULMONARY VALVE; AORTIC VALVE; AORTIC INSUFFICIENCY;
D O I
10.1016/1010-7940(92)90245-S
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Excellent clinical results with pulmonary autografts and experimental evidence that the pulmonary valve can withstand the higher stress in the systemic circulation led us to use the cryopreserved pulmonary allograft for aortic valve replacement. From September 1988 to March 1991, 45 consecutive patients (59.9 +/- 12.0 years, 25 men and 20 women) received a cryopreserved pulmonary allograft in the aortic position from our hospital based valve bank. All allografts were inserted freehand in the subcoronary position. There were 3 in-hospital deaths (7%) and 1 patient had severe valvular incompetence immediately postoperatively requiring reoperation after 4 weeks. Forty-one patients were followed at 3-6 month interval for 14.7 +/- 7.8 months (3-28 months) and valve performance was assessed routinely by means of color flow Doppler echocardiography: 34 patients (83%) had no or trivial aortic valve regurgitation. Valvular incompetence class II was present in 2 patients (5%) whereas 3 (7%) demonstrated class II-III. Severe aortic regurgitation (class III-IV) could be detected in 2 patients (5%). Both had to undergo reoperation 4 months and 15 months, respectively, postoperatively. Macroscopic and histological evaluation of the explanted valves demonstrated absence of significant degeneration. We assume that a mismatch in size between allograft and aortic annulus could have lead to dilatation of the allograft valve ring and consequently to valvular incompetence. Pulmonary cryopreserved allografts achieve acceptable short-term results which can be improved if initial technical problems can be avoided.
引用
收藏
页码:485 / 489
页数:5
相关论文
共 17 条
  • [1] Armiger L.C., Gavin J.B., Barratt-Boyes B.G., Histological assessment of orthotopic aortic valve leaflet allograft: Its role in selecting graft pre-treatment, Pathology, 15, pp. 67-73, (1983)
  • [2] Barratt-Boyes B.G., Roche A.H.G., Subramanyan R., Pemberton J.R., Whitlock R.M.L., Long-term follow-up of patients with the antibiotic sterilized aortic homograft valve inserted freehand in the aortic position, Circulation, 75, pp. 768-777, (1987)
  • [3] Gorczynski A., Trenker M., Anisimowicz L., Gutkowski R., Drapella A., Kwiatkowska E., Dobke M., Biomechanics of the pulmonary autograft valve in the aortic position, Thorax, 37, pp. 535-539, (1982)
  • [4] Gula G., Wain W.H., Ross D.N., Ten years experience with pulmonary autograft replacements for aortic valve disease, Ann Thorac Surg, 28, pp. 392-396, (1979)
  • [5] Kaplan E.L., Meier P., Non-parametric estimations from incomplete observations, J Am Stat Assoc, 53, pp. 457-481, (1958)
  • [6] Konertz W., Schwammenthal E., Hachenberg T., Spital G., Breithardt G., Scheldt H.H., Pulmonalklappenallograft in Aortenposition - Frühergebnisse bei 30 konsekutiven Patienten, Z Herz-, Thorax-, Gefäßchir, 5, pp. 68-74, (1991)
  • [7] Livi U., Abdulla A.-K., Parker R., Olsen E.J., Ross D.N., Viability and morphology of aortic and pulmonary homografts, J Thorac Cardiovasc Surg, 93, pp. 755-760, (1987)
  • [8] Manhas D.R., Rittenhouse E.A., Mohri H., Merendino K.A., Aortic valve replacement with a pulmonic valve allograft, J Thorac Cardiovasc Surg, 59, pp. 432-436, (1970)
  • [9] Matsuki O., Okita Y., Almeida R.S., McGoldrich J.P., Hooper T.L., Robles A., Ross D.N., Two decades experience with aortic valve replacement with pulmonary autograft, J Thorac Cardiovasc Surg, 95, pp. 705-711, (1988)
  • [10] McGrath, Gonzalez-Lavin L., Graf D., Pulmonary homograft implantation for ventricular outflow tract reconstruction: Early phase results, Ann Thorac Surg, 3, pp. 273-277, (1988)