FIBEROPTIC GLUCOSE SENSOR WITH ELECTROCHEMICAL GENERATION OF INDICATOR REAGENT

被引:16
作者
GUNASINGHAM, H
TAN, CH
SEOW, JKL
机构
[1] Department of Chemistry, National University of Singapore, Kent Ridge
关键词
D O I
10.1021/ac00206a022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemlcally generated tetrathlafulvalene redox mediator provides a convenient and reversible indicator reagent for a glucose fiber-optic sensor. The fabrication and characterization of this sensor based on a thin-layer cell configuration are described. The performance of the fiber-optic sensor is compared with that of an amperometric enzyme electrode In flow-injection and steady-state analyses. The upper limit of the linear range In the flow-Injection mode is about 12 mM, whereas in the steady-state mode It Is about 3 mM. The sensor Is less prone to Interfering species and dissolved oxygen. It can be used continuously for 2 days without significant loss of activity. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:755 / 759
页数:5
相关论文
共 12 条
[1]   FIBER-OPTIC SENSOR FOR THE DETERMINATION OF GLUCOSE USING MICELLAR ENHANCED CHEMI-LUMINESCENCE OF THE PEROXYOXALATE REACTION [J].
ABDELLATIF, MS ;
GUILBAULT, GG .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2671-2674
[2]   AMPEROMETRIC ENZYME ELECTRODES .2. CONDUCTING SALTS AS ELECTRODE MATERIALS FOR THE OXIDATION OF GLUCOSE-OXIDASE [J].
ALBERY, WJ ;
BARTLETT, PN ;
CRASTON, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :223-235
[3]   ENZYME-BASED FIBER OPTIC SENSOR [J].
ARNOLD, MA .
ANALYTICAL CHEMISTRY, 1985, 57 (02) :565-566
[4]  
BLICK KE, 1985, PRINCIPLES CLIN CHEM, pCH10
[5]   ION AND ELECTRON-TRANSPORT IN STABLE, ELECTROACTIVE TETRATHIAFULVALENE POLYMER COATED ELECTRODES [J].
KAUFMAN, FB ;
SCHROEDER, AH ;
ENGLER, EM ;
KRAMER, SR ;
CHAMBERS, JQ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1980, 102 (02) :483-488
[6]   FIBER-OPTIC SENSORS FOR BIOMEDICAL APPLICATIONS [J].
PETERSON, JI ;
VUREK, GG .
SCIENCE, 1984, 224 (4645) :123-127
[7]   CHEMICAL SENSORS BASED ON FIBER OPTICS [J].
SEITZ, WR .
ANALYTICAL CHEMISTRY, 1984, 56 (01) :A16-&
[8]   CHEMICAL SENSORS BASED ON IMMOBILIZED INDICATORS AND FIBER OPTICS [J].
SEITZ, WR .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 19 (02) :135-173
[9]   OPTICAL SENSORS .34. FIBER OPTIC GLUCOSE BIOSENSOR WITH AN OXYGEN OPTRODE AS THE TRANSDUCER [J].
TRETTNAK, W ;
LEINER, MJP ;
WOLFBEIS, OS .
ANALYST, 1988, 113 (10) :1519-1523
[10]  
WALTER B, 1983, ANAL CHEM, V55, pA499