REPRODUCIBILITY AND RESPONSIVENESS OF THE VF-14 - AN INDEX OF FUNCTIONAL IMPAIRMENT IN PATIENTS WITH CATARACTS

被引:132
作者
CASSARD, SD
PATRICK, DL
DAMIANO, AM
LEGRO, MW
TIELSCH, JM
DIENERWEST, M
SCHEIN, OD
JAVITT, JC
BASS, EB
STEINBERG, EP
机构
[1] JOHNS HOPKINS UNIV,SCH MED,BALTIMORE,MD 21205
[2] UNIV WASHINGTON,SCH PUBL HLTH & COMMUNITY MED,SEATTLE,WA 98195
[3] VET ADM MED CTR,HLTH SERV RES & DEV FIELD OFF,SEATTLE,WA 98108
[4] HLTH TECHNOL ASSOCIATES INC,WASHINGTON,DC
[5] GEORGETOWN UNIV,SCH MED,WORTHEN CTR EYE CARE RES,WASHINGTON,DC 20057
关键词
D O I
10.1001/archopht.1995.01100120038005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To assess the test-retest reliability and responsiveness of the VF-14, which is an index of functional impairment in patient with cataracts. Design: Observational longitudinal study. Patients were enrolled prior to undergoing their first cataract surgery between July 15 and December 15, 1991, and they were followed up for 1 year after surgery. Setting: Patients were recruited from 72 ophthalmologists' practices in three US cities. Patients: Five hundred fifty-two patients who had undergone a surgical procedure in only one eye by the 4-month postoperative follow-up (responsiveness analyses) and a subset of these (n = 426) who had not subsequently undergone surgery for the second eye by the 12-month postoperative follow-up (reproducibility analyses). Main Outcome Measures: Two health status measures (the VF-14 and the Sickness Impact Profile, two global measures of a patient's trouble and satisfaction with his or her vision, and best corrected visual acuity in each eye. Results: The VF-14 is highly reproducible, with an intraclass correlation coefficient of .79 when patient-rated criteria are used to define stable patients. The intraclass correlation coefficient was lower (.57 to .71) when various measures of visual acuity were used to define stable patients. The VF-14 is also about three times more responsive to a change in vision than the Sickness Impact Profile, which is a generic health status measure (effect size of approximately 1.00 vs 0.30). Estimates of the responsiveness of the VF-14 and the Sickness Impact Profile were not associated with preoperative visual acuity in the operated on or better eye. Responsiveness of the VF-14, however, was higher in patients with greater self-rated trouble with vision preoperatively. Conclusions: The VF-14 was reproducible in stable patients during an 8-month period, and it was more responsive to clinically significant changes in vision than was a generic health status measure tie, the Sickness Impact Profile).
引用
收藏
页码:1508 / 1513
页数:6
相关论文
共 20 条
  • [1] HEALTH-STATUS MEASURES - AN OVERVIEW AND GUIDE FOR SELECTION
    BERGNER, M
    ROTHMAN, ML
    [J]. ANNUAL REVIEW OF PUBLIC HEALTH, 1987, 8 : 191 - 210
  • [2] THE SICKNESS IMPACT PROFILE - DEVELOPMENT AND FINAL REVISION OF A HEALTH-STATUS MEASURE
    BERGNER, M
    BOBBITT, RA
    CARTER, WB
    GILSON, BS
    [J]. MEDICAL CARE, 1981, 19 (08) : 787 - 805
  • [3] BERNTHPETERSEN P, 1981, ACTA OPHTHALMOL, V59, P198
  • [4] BRENNER MH, 1995, MED CARE, V33, pAS236
  • [5] VISION CHANGE AND QUALITY-OF-LIFE IN THE ELDERLY - RESPONSE TO CATARACT-SURGERY AND TREATMENT OF OTHER CHRONIC OCULAR CONDITIONS
    BRENNER, MH
    CURBOW, B
    JAVITT, JC
    LEGRO, MW
    SOMMER, A
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (05) : 680 - 685
  • [6] COHEN J, 1988, STATISTICAL POWER AN
  • [7] DAMIANO AM, 1995, MED CARE, V33, pAS120
  • [8] DEYO RA, 1984, HEALTH SERV RES, V19, P275
  • [9] REPRODUCIBILITY AND RESPONSIVENESS OF HEALTH-STATUS MEASURES - STATISTICS AND STRATEGIES FOR EVALUATION
    DEYO, RA
    DIEHR, P
    PATRICK, DL
    [J]. CONTROLLED CLINICAL TRIALS, 1991, 12 (04): : S142 - S158
  • [10] DEYO RA, 1978, MED CARE S3, V27, pS254