Techniques in Vascular and Interventional Radiology Drug Delivery Technologies in the Superficial Femoral Artery

被引:2
作者
Brahmbhatt, Akshaar [1 ,2 ,3 ]
Misra, Sanjay [1 ,2 ]
机构
[1] Mayo Clin, Dept Radiol, Vasc & Intervent Radiol Translat Lab, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN USA
[3] Rutgers New Jersey Med Sch, Newark, NJ USA
基金
美国国家卫生研究院;
关键词
SFA; PAD; drug-coated balloon; drug-eluting stent;
D O I
10.1053/j.tvir.2016.04.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Peripheral arterial disease (PAD) affects over 8 million people in the United States alone. Although great strides have been made in reducing the burden of cardiovascular disease the prevalence of PAD is expected to rise with the age of global population. PAD characterized by narrowing of arterial blood can be asymptomatic or cause limb threatening claudication. It has been classically treated with bypass, but these techniques have been supplanted by endovascular therapy. Plain old balloon angioplasty has been successful in helping revascularize lesions, but its effect has not been durable because of restenosis. This prompted the creation of several technologies aimed at reducing restenosis. These advances slowly improved outcomes and the durability of endovascular management. Among the main tools used in current endovascular practice are drug-delivery devices aimed at inhibiting the inflammatory and proliferative pathways that lead to restenosis. This article examines the current drug-delivery technologies used in the superficial femoral artery. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 74 条
[1]   High-Speed Rotational Atherectomy Before Paclitaxel-Eluting Stent Implantation in Complex Calcified Coronary Lesions The Randomized ROTAXUS (Rotational Atherectomy Prior to Taxus Stent Treatment for Complex Native Coronary Artery Disease) Trial [J].
Abdel-Wahab, Mohamed ;
Richardt, Gert ;
Buettner, Heinz Joachim ;
Toelg, Ralph ;
Geist, Volker ;
Meinertz, Thomas ;
Schofer, Joachim ;
King, Lamin ;
Neumann, Franz-Josef ;
Khattab, Ahmed A. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) :10-19
[2]   Current Treatment of In-Stent Restenosis [J].
Alfonso, Fernando ;
Byrne, Robert A. ;
Rivero, Fernando ;
Kastrati, Adnan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (24) :2659-2673
[3]   Five-year follow-up of the Sirolimus-Eluting Stents vs Vascular Brachytherapy for Bare Metal In-Stent Restenosis (SISR) trial [J].
Alli, Oluseun O. ;
Teirstein, Paul S. ;
Satler, Lowell ;
Sketch, Michael H., Jr. ;
Popma, Jeffery J. ;
Mauri, Laura ;
Wang, Hong ;
Schleckser, Patricia A. ;
Cohen, Sidney A. ;
Holmes, David R., Jr. .
AMERICAN HEART JOURNAL, 2012, 163 (03) :438-445
[4]  
Axel DI, 1997, CIRCULATION, V96, P636
[5]   Meta-Analysis of Drug-Eluting Balloon Angioplasty and Drug-Eluting Stent Placement for Infrainguinal Peripheral Arterial Disease [J].
Baerlocher, Mark Otto ;
Kennedy, Sean Alexander ;
Rajebi, Mohammad Reza ;
Baerlocher, Felix J. ;
Misra, Sanjay ;
Liu, David ;
Nikolic, Boris .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (04) :459-473
[6]   In-stent stenosis: pathology and implications for the development of drug eluting stents [J].
Bennett, MR .
HEART, 2003, 89 (02) :218-224
[7]   The molecular mechanisms of hemodialysis vascular access failure [J].
Brahmbhatt, Akshaar ;
Remuzzi, Andrea ;
Franzoni, Marco ;
Misra, Sanjay .
KIDNEY INTERNATIONAL, 2016, 89 (02) :303-316
[8]   Sirolimus-eluting biodegradable poly-L-lactide stent for peripheral vascular application:: A preliminary study in porcine carotid arteries [J].
Buenger, Carsten Michael ;
Grabow, Niels ;
Sternberg, Katrin ;
Kroeger, Christina ;
Ketner, Lisa ;
Schmitz, Klaus-Peter ;
Kreutzer, Hans Juergen ;
Ince, Hueseyin ;
Nienaber, Christoph A. ;
Klar, Ernst ;
Schareck, Wolfgang .
JOURNAL OF SURGICAL RESEARCH, 2007, 139 (01) :77-82
[9]  
Chu TM, 2015, J CARDIOVASC SURG TO
[10]   NON-SURGICAL PLACEMENT OF ARTERIAL ENDOPROSTHESES - A NEW TECHNIQUE USING NITINOL WIRE [J].
CRAGG, A ;
LUND, G ;
RYSAVY, J ;
CASTANEDA, F ;
CASTANEDAZUNIGA, W ;
AMPLATZ, K .
RADIOLOGY, 1983, 147 (01) :261-263