IMMUNOASSAY BY TIME-RESOLVED ELECTROGENERATED LUMINESCENCE

被引:48
|
作者
KANKARE, J
HAAPAKKA, K
KULMALA, S
NANTO, V
ESKOLA, J
TAKALO, H
机构
[1] UNIV TURKU,DEPT CLIN CHEM,SF-20500 TURKU 50,FINLAND
[2] UNIV TURKU,CTR BIOTECHNOL,SF-20521 TURKU,FINLAND
关键词
CHEMILUMINESCENCE; IMMUNOASSAY; ELECTROLUMINESCENCE IMMUNOASSAY; PHOSPHOLIPASE-A2;
D O I
10.1016/0003-2670(92)85044-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunoanalytical method based on electrogenerated luminescence was developed in which the labelling compound is the terbium chelate of 2,6-bis[N,N-bis(carboxymethyl)aminomethyl]-4-benzoylphenol which is linked by a thioureido group to the antibody. The sandwich complex of the labelled antibody, antigen and antibody immobilized on the surface of an aluminium electrode is excited by an electrical pulse and, after a short delay from the end of the pulse, light emission is measured. The electroluminescence immunoassay is exemplified by the heterogeneous and homogeneous assays of human pancreatic phospholipase A2, for which both assay methods give a reasonably good linearity in the range 10-300 ng ml-1.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 50 条
  • [21] Time-resolved fluoroimmunoassay of plasma daidzein and genistein
    Wang, GJ
    Lapcík, O
    Hampl, R
    Uehara, M
    Al-Maharik, N
    Stumpf, K
    Mikola, H
    Wähälä, K
    Adlercreutz, H
    STEROIDS, 2000, 65 (06) : 339 - 348
  • [22] Influence of Luminescence Quantum Yield, Surface Coating, and Functionalization of Quantum Dots on the Sensitivity of Time-Resolved FRET Bioassays
    Wegner, K. David
    Phung Thi Lanh
    Jennings, Travis
    Oh, Eunkeu
    Jain, Vaibhav
    Fairclough, Simon M.
    Smith, Jason M.
    Giovanelli, Emerson
    Lequeux, Nicolas
    Pons, Thomas
    Hildebrandt, Niko
    ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (08) : 2881 - 2892
  • [23] CD8 cell counting in whole blood by a paper-based time-resolved fluorescence lateral flow immunoassay
    Xiao, Wei
    Liang, Jiajie
    Zhang, Ying
    Zhang, Yan
    Teng, Peijun
    Cao, Dongni
    Zou, Siyi
    Xu, Tao
    Zhao, Jianfu
    Tang, Yong
    ANALYTICA CHIMICA ACTA, 2021, 1179
  • [24] A new measure of xenobiotic toxicity to the first-line human defence system from the time-resolved phagocyte luminescence
    Kochel, B
    Sajewicz, W
    BULLETIN OF MATHEMATICAL BIOLOGY, 1997, 59 (05) : 897 - 910
  • [25] Luminescence Amplification by Enzymatic Eu2+ Oxidation to Eu3+ for Time-Resolved Peroxidase Activity Measurement
    Matsumoto, Kazuko
    Kimura, Hiroko
    Kon, Nobuko
    Yoshida, Ken-ichi
    Abo, Mitsuru
    Yoshimura, Etsuro
    ANALYTICAL SCIENCES, 2013, 29 (10) : 971 - 977
  • [26] Detection of anticardiolipin antibody IgG by time-resolved fluoroimmunoassay
    Ye, Yan
    Hu, Zhigang
    Liu, Jie
    Chen, Guoqian
    Zhou, Yaohong
    Yu, Lei
    CLINICAL RHEUMATOLOGY, 2012, 31 (09) : 1339 - 1345
  • [27] Millifluidics for Time-resolved Mapping of the Growth of Gold Nanostructures
    Krishna, Katla Sai
    Navin, Chelliah V.
    Biswas, Sanchita
    Singh, Varshni
    Ham, Kyungmin
    Bovenkamp, G. Lisa
    Theegala, Chandra S.
    Miller, Jeffery T.
    Spivey, James J.
    Kumar, Challa S. S. R.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (14) : 5450 - 5456
  • [28] Immunoassay on a single microparticle:: the effect of particle size and number on a miniaturized time-resolved fluorometric assay of free prostate-specific antigen
    Härmä, H
    Lehtinen, P
    Takalo, H
    Lövgren, T
    ANALYTICA CHIMICA ACTA, 1999, 387 (01) : 11 - 19
  • [29] Rapid time-resolved fluoroimmunoassay for the screening of monensin residues in eggs
    Hagren, V
    Peippo, P
    Tuomola, M
    Lövgren, T
    ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) : 164 - 168
  • [30] Rapid analysis of phytoestrogens in human urine by time-resolved fluoroimmunoassay
    Uehara, M
    Lapcík, O
    Hampl, R
    Al-Maharik, N
    Mäkelä, T
    Wähälä, K
    Mikola, H
    Adlercreutz, H
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2000, 72 (05) : 273 - 282