Noise production in ceramic-on-ceramic total hip arthroplasty is associated with lower patient satisfaction and hip scores

被引:6
作者
Gillespie, James A. [1 ]
Kennedy, John W. [1 ]
Patil, Sanjeev R. [1 ]
Meek, Dominic R. M. [1 ]
机构
[1] Queen Elizabeth Univ Hosp, Dept Trauma & Orthopaed, 1345 Govan Rd, Glasgow G51 4TF, Lanark, Scotland
关键词
Total hip arthroplasty; Ceramic; Noise; Squeak;
D O I
10.1016/j.jor.2016.06.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ceramic-on-ceramic total hip arthroplasties (THA) are commonly implanted. We investigated the incidence of noise in ceramic-on-ceramic and determined any association with patient satisfaction and hip scores. Methods: We recruited 140 THA. Questionnaires were completed to assess the incidence and frequency of noise, and satisfaction level. Hip and SF-12 scores were recorded. Results: Forty-two patients (30%) were aware of noise production. Patients with noise production had lower satisfaction, mean hip and SF-12 scores than those with silent hips. Conclusion: Given the high incidence of noise in ceramic-on-ceramic THA, patients should be counselled on this risk pre-operatively. (C) 2016 Prof. PK Surendran Memorial Education Foundation. Published by Elsevier, a division of Reed Elsevier India, Pvt. Ltd. All rights reserved.
引用
收藏
页码:282 / 284
页数:3
相关论文
共 15 条
[1]  
Bizot P, 2001, CLIN ORTHOP RELAT R, P85
[2]   Hip Squeaking A 10-Year Follow-Up Study [J].
Chevillotte, Christophe ;
Pibarot, Vincent ;
Carret, Jean-Paul ;
Bejui-Hugues, Jacques ;
Guyen, Olivier .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :1008-1013
[3]   The 2009 Frank Stinchfield Award "Hip Squeaking'' A Biomechanical Study of Ceramic-on-ceramic Bearing Surfaces [J].
Chevillotte, Christophe ;
Trousdale, Robert T. ;
Chen, Qingshan ;
Guyen, Olivier ;
An, Kai-Nan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :345-350
[4]   Squeaking After Third-Generation Ceramic-on-Ceramic Total Hip Arthroplasty [J].
Haq, Rehan-Ul ;
Park, Kyung Soon ;
Seon, Jong Keun ;
Yoon, Taek Rim .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :909-915
[5]   The Squeaking Hip: A Phenomenon of Ceramic-on-Ceramic Total Hip Arthroplasty [J].
Jarrett, Christopher A. ;
Ranawat, Amar S. ;
Bruzzone, Matteo ;
Blum, Yossef C. ;
Rodriguez, Jose A. ;
Ranawat, Chitranjan S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06) :1344-1349
[6]   High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings [J].
Keurentjes, J. C. ;
Kuipers, R. M. ;
Wever, D. J. ;
Schreurs, B. W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (06) :1438-1443
[7]   Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty [J].
Lusty, P. J. ;
Tai, C. C. ;
Sew-Hoy, R. P. ;
Walter, W. L. ;
Walter, W. K. ;
Zicat, B. A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (12) :2676-2683
[8]   Incidence of 'Squeaking' After Ceramic-on-Ceramic Total Hip Arthroplasty [J].
Mai, Kenny ;
Verioti, Christopher ;
Ezzet, Kace A. ;
Copp, Steven N. ;
Walker, Richard H. ;
Colwell, Clifford W., Jr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :413-417
[9]   Maximising response to postal questionnaires - A systematic review of randomised trials in health research [J].
Nakash R.A. ;
Hutton J.L. ;
Jørstad-Stein E.C. ;
Gates S. ;
Lamb S.E. .
BMC Medical Research Methodology, 6 (1)
[10]  
Regis D, 2008, ORTHOPAEDICS, V31