Noise production in ceramic-on-ceramic total hip arthroplasty is associated with lower patient satisfaction and hip scores

被引:6
作者
Gillespie, James A. [1 ]
Kennedy, John W. [1 ]
Patil, Sanjeev R. [1 ]
Meek, Dominic R. M. [1 ]
机构
[1] Queen Elizabeth Univ Hosp, Dept Trauma & Orthopaed, 1345 Govan Rd, Glasgow G51 4TF, Lanark, Scotland
关键词
Total hip arthroplasty; Ceramic; Noise; Squeak;
D O I
10.1016/j.jor.2016.06.018
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ceramic-on-ceramic total hip arthroplasties (THA) are commonly implanted. We investigated the incidence of noise in ceramic-on-ceramic and determined any association with patient satisfaction and hip scores. Methods: We recruited 140 THA. Questionnaires were completed to assess the incidence and frequency of noise, and satisfaction level. Hip and SF-12 scores were recorded. Results: Forty-two patients (30%) were aware of noise production. Patients with noise production had lower satisfaction, mean hip and SF-12 scores than those with silent hips. Conclusion: Given the high incidence of noise in ceramic-on-ceramic THA, patients should be counselled on this risk pre-operatively. (C) 2016 Prof. PK Surendran Memorial Education Foundation. Published by Elsevier, a division of Reed Elsevier India, Pvt. Ltd. All rights reserved.
引用
收藏
页码:282 / 284
页数:3
相关论文
共 15 条
  • [1] Bizot P, 2001, CLIN ORTHOP RELAT R, P85
  • [2] Hip Squeaking A 10-Year Follow-Up Study
    Chevillotte, Christophe
    Pibarot, Vincent
    Carret, Jean-Paul
    Bejui-Hugues, Jacques
    Guyen, Olivier
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 1008 - 1013
  • [3] The 2009 Frank Stinchfield Award "Hip Squeaking'' A Biomechanical Study of Ceramic-on-ceramic Bearing Surfaces
    Chevillotte, Christophe
    Trousdale, Robert T.
    Chen, Qingshan
    Guyen, Olivier
    An, Kai-Nan
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) : 345 - 350
  • [4] Squeaking After Third-Generation Ceramic-on-Ceramic Total Hip Arthroplasty
    Haq, Rehan-Ul
    Park, Kyung Soon
    Seon, Jong Keun
    Yoon, Taek Rim
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 909 - 915
  • [5] The Squeaking Hip: A Phenomenon of Ceramic-on-Ceramic Total Hip Arthroplasty
    Jarrett, Christopher A.
    Ranawat, Amar S.
    Bruzzone, Matteo
    Blum, Yossef C.
    Rodriguez, Jose A.
    Ranawat, Chitranjan S.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (06) : 1344 - 1349
  • [6] High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings
    Keurentjes, J. C.
    Kuipers, R. M.
    Wever, D. J.
    Schreurs, B. W.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (06) : 1438 - 1443
  • [7] Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty
    Lusty, P. J.
    Tai, C. C.
    Sew-Hoy, R. P.
    Walter, W. L.
    Walter, W. K.
    Zicat, B. A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (12) : 2676 - 2683
  • [8] Incidence of 'Squeaking' After Ceramic-on-Ceramic Total Hip Arthroplasty
    Mai, Kenny
    Verioti, Christopher
    Ezzet, Kace A.
    Copp, Steven N.
    Walker, Richard H.
    Colwell, Clifford W., Jr.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) : 413 - 417
  • [9] Maximising response to postal questionnaires - A systematic review of randomised trials in health research
    Nakash R.A.
    Hutton J.L.
    Jørstad-Stein E.C.
    Gates S.
    Lamb S.E.
    [J]. BMC Medical Research Methodology, 6 (1)
  • [10] Regis D, 2008, ORTHOPAEDICS, V31