A NEW APPROACH FOR THE REMOVAL OF CHLORATE IMPURITY FROM MILITARY GRADE AMMONIUM PERCHLORATE USING STABILIZED ZERO-VALENT IRON NANOPARTICLES

被引:0
|
作者
Zarei, Ali Reza [1 ]
Ghavi, Azam [1 ]
机构
[1] Malek Ashtar Univ Technol, Fac Chem & Chem Engn, POB 15875-1774, Tehran, Iran
关键词
chlorate removal; nanoscale zero-valent iron (nZVI); ammonium perchlorate; impurity;
D O I
10.1615/IntJEnergeticMaterialsChemProp.2016014326
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
In this work we propose a new technique for the removal and elimination of chlorate impurity from ammonium perchlorate based on nanotechnology using nanoscale zero-valent iron (nZVI). At first, stabilized nZVI was synthesized using the borohydride reduction method in the presence of starch as a stabilizing agent, characterized by transmission electron microscopy (TEM) and dynamic light scattering (DLS) and then used for the removal of chlorate in an ammonium perchlorate solution. The effects of the key parameters in the chlorate elimination process, including pH, temperature, amount of nZVI, and reaction time, were investigated. The experimental results showed that under optimum conditions, chlorate can be completely removed from an ammonium perchlorate solution by nZVI within 90 min at room temperature.
引用
收藏
页码:185 / 195
页数:11
相关论文
共 50 条
  • [1] Reductive Removal of Selenate in Water Using Stabilized Zero-Valent Iron Nanoparticles
    Liu, Hongfang
    Cai, Zhengqing
    Zhao, Xiao
    Zhao, Dongye
    Qian, Tianwei
    Bozack, Michael
    Zhang, Mingang
    WATER ENVIRONMENT RESEARCH, 2016, 88 (08) : 694 - 703
  • [2] Perchlorate degradation in aqueous solution using chitosan-stabilized zero-valent iron nanoparticles
    Xie, Yanhua
    Yi, Yan
    Qin, Yinhong
    Wang, Lanting
    Liu, Guoming
    Wu, Yulan
    Diao, Zhiqiang
    Zhou, Tingheng
    Xu, Mo
    SEPARATION AND PURIFICATION TECHNOLOGY, 2016, 171 : 164 - 173
  • [3] Perchlorate Removal Using a Minimized Dosage of Electrodeposited Zero-Valent Iron
    Wang, Chuan
    Liu, Tianfu
    Bu, Fang
    Liu, Hong
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2015, 141 (03)
  • [4] A Simple and Sensitive Approach for Determination of Iron Impurity in Military Grade Ammonium Perchlorate
    Zarei, Ali Reza
    JORDAN JOURNAL OF CHEMISTRY, 2013, 8 (04) : 253 - 261
  • [5] Synthesis, Characterization, and Application of Stabilized-Ni/ Fe Bimetallic Nanoparticles for the Selective Elimination of Chlorate Impurity in Military Grade Ammonium Perchlorate
    Zarei, Ali Reza
    Moloudi, Ali
    Hosseini, Seyed Ghorban
    CENTRAL EUROPEAN JOURNAL OF ENERGETIC MATERIALS, 2017, 14 (01): : 120 - 133
  • [6] Heavy metal removal from wastewater using zero-valent iron nanoparticles
    Chen, S. Y.
    Chen, W. H.
    Shih, C. J.
    WATER SCIENCE AND TECHNOLOGY, 2008, 58 (10) : 1947 - 1954
  • [7] Pb(II) Removal from Aqueous Solutions by Adsorption on Stabilized Zero-Valent Iron Nanoparticles-A Green Approach
    Sepehri, Saloome
    Kanani, Elahe
    Abdoli, Sima
    Rajput, Vishnu D.
    Minkina, Tatiana
    Asgari Lajayer, Behnam
    WATER, 2023, 15 (02)
  • [8] An analysis of boron removal from water using modified zero-valent iron nanoparticles
    Khorsandi, Hassan
    Azarnioush, Aliye
    Aghapour, Ali-Ahmad
    Nemati, Sepideh
    Karimzadeh, Sima
    Khalkhali, Hamid-Reza
    DESALINATION AND WATER TREATMENT, 2017, 70 : 284 - 289
  • [9] Rapid and complete destruction of perchlorate in water and ion-exchange brine using stabilized zero-valent iron nanoparticles
    Xiong, Zhong
    Zhao, Dongye
    Pan, Gang
    WATER RESEARCH, 2007, 41 (15) : 3497 - 3505
  • [10] Removal of mercury from brine by using zero-valent iron
    Kluczka, Joanna
    PRZEMYSL CHEMICZNY, 2009, 88 (10): : 1117 - 1120