MASS AND ENERGY ANALYSES OF AN AUSI LIQUID-METAL ION-SOURCE

被引:5
|
作者
KREISSIG, U [1 ]
KAHN, A [1 ]
RUEDENAUER, FG [1 ]
STEIGER, W [1 ]
机构
[1] AUSTRIAN RES CTR,A-2444 SEIBERSDORF,AUSTRIA
关键词
D O I
10.1088/0022-3727/23/7/033
中图分类号
O59 [应用物理学];
学科分类号
摘要
Mass and energy analyses of ions emitted from an AuSi eutectic alloy liquid metal ion source (LMIS) were carried out using a tandem double-focusing mass spectrometer. In the investigated ion current range between below 1 mu A and 10 mu A a great variety of molecules and clusters were detected. The field strength at the apex of the Taylor cone was estimated from post-ionisation probability to be 20 V nm-1for silicon ions and 30 V nm-1for gold ions at 10 mu A emission current. The energy spread of different ion species depends on the charge-to-mass ratio and on the total extracted ion current. For the ion current dependence of the energy spread a nearly two thirds power dependence was obtained. The energy width varies between 10 eV and 100 eV for Au ion species and between 10 eV and 20 eV for Si ion species. The energy deficit decreases with increasing ion current for Au and Si ion species. The authors assume a decrease of the field-dependent activation energy of field evaporation together with growing asymmetry in the energy distributions. © 1990 IOP Publishing Ltd.
引用
收藏
页码:959 / 963
页数:5
相关论文
共 50 条
  • [1] ANGULAR-DISTRIBUTION OF IONS FROM A AUSI LIQUID-METAL ION-SOURCE
    RAO, S
    BELL, AE
    SCHWIND, GA
    SWANSON, LW
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (03): : 2258 - 2264
  • [2] CHARACTERISTICS OF A LIQUID-METAL ION-SOURCE
    ZHOU, F
    MA, M
    WANG, W
    HUA, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1985, 6 (1-2): : 143 - 145
  • [3] APPLICATION OF A LIQUID-METAL ION-SOURCE TO SECONDARY ION MASS-SPECTROMETRY
    GNASER, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 319 (6-7): : 719 - 723
  • [4] EVALUATION OF A LIQUID-METAL ION-SOURCE FOR SECONDARY ION MASS-SPECTROMETRY
    GNASER, H
    RUDENAUER, FG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 218 (1-3): : 303 - 306
  • [5] BEAM DYNAMICS OF A LIQUID-METAL ION-SOURCE
    WHEALTON, JH
    MESZAROS, PS
    ROTHE, KE
    RARIDON, RJ
    RYAN, PM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 568 - 570
  • [6] DEVELOPMENT OF AN ARSENIC LIQUID-METAL ION-SOURCE
    UMEMURA, K
    KAWANAMI, Y
    ISHITANI, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 37-8 : 208 - 211
  • [7] STUDIES WITH A CAPILLARY LIQUID-METAL ION-SOURCE
    MAIR, GLR
    THOMS, S
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1986, 19 (10) : L203 - L206
  • [8] HEATING EFFECTS IN A LIQUID-METAL ION-SOURCE
    MAIR, GLR
    AITKEN, KL
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1984, 17 (01) : L13 - L17
  • [9] A LIQUID-METAL ION-SOURCE FOR SPACE APPLICATION
    RUEDENAUER, FG
    STEIGER, W
    ARENDS, H
    FEHRINGER, M
    SCHMIDT, R
    JOURNAL DE PHYSIQUE, 1988, 49 (C-6): : 161 - 166
  • [10] MINIATURIZED LIQUID-METAL ION-SOURCE (MILMIS)
    MITTERAUER, J