Evaluation of Image Quality and Dose in Abdominal and Pelvic Helical CT in Patients with Lymphoma

被引:0
作者
Garcia-Castano, Begona [1 ]
Rodriguez, Ricardo [2 ,3 ]
Calzado, Alfonso [2 ]
Arenas, Angel [2 ,4 ]
Cuevas, Alfredo [5 ]
Gomez, Nieves [6 ]
Turrero, Agustin [7 ]
Maria Moran, Luz [8 ]
Moran, Pilar
机构
[1] Hosp Mostoles, Serv Radiodiagnost, Rio Jucar S-N, Madrid 28935, Spain
[2] Univ Complutense Madrid, Dept Radiol & MF, Madrid, Spain
[3] Hosp Cin San Carlos, Serv Radiodiagnost, Madrid, Spain
[4] Hosp 12 Octubre, Serv Radiodiagnost, Madrid, Spain
[5] Hosp Aire, Serv Radiodiagnost, Madrid, Spain
[6] Hosp La Paz, Serv Radiodiagnost, Madrid, Spain
[7] Univ Complutense Madrid, Dept Estadist & IO, Madrid, Spain
[8] Hosp Univ Gregorio Maranon, Serv Radiodiagnost, Madrid, Spain
来源
RADIOLOGIA | 2005年 / 47卷 / 05期
关键词
helical CT; abdomen-pelvis; radiation dose; image quality; quality criteria;
D O I
10.1016/S0033-8338(05)72846-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study is to evaluate the quality of pelvic and abdominal CT images performed for lymphoma according to the criteria proposed in the European Commission Guidelines on radiation imaging.(En castellano dice: la Guia de la Comision Europea. Lo que pasa es que hay muchas guias publicadas por la Comision: aseguranse que sea esta la citada) Material and methods: The criteria were evaluated in a sample of 100 patients attended at five public hospitals in the Autonomous Community of Madrid. All patients underwent single-slice helical CT studies. Fulfillment of the imaging criteria in the selected images was evaluated by five radiologists, one from each center, working independently. The Index of Image Quality (IIQ) was determined for the complete abdominal and pelvic examination. The dose was also measured to estimate the values of the CT Dose Index (CTDIw), Dose by Length Product (DLP), and effective dose (E). Results: A high rate of fulfillment of the criteria was found for individual abdominal images. In the pelvis, the rate of fulfillment was lower, especially for three criteria. The IIQ for each center was between 83%-92%, with variable degrees of internal deviation. The mean values of CTDIw per center were between 16-23 mGy; DLP values were between 430 and 750 mGy cm, and the effective dose was 7-12 mSv. In general, no correlation was found between IIQ and dose per patient, either for the entire sample (r = 0.04) or by centers (r 0.36) pound. Conclusions: The utility of the European Union's Quality Criteria was confirmed. We have elaborated a single list of criteria of image quality and suggest reference dosage levels for abdominal-pelvic CT examinations in patients with lymphoma.
引用
收藏
页码:263 / 272
页数:10
相关论文
共 19 条
  • [1] [Anonymous], 2010, TRAINING COURSE SERI
  • [2] Quality criteria implementation for brain and lumbar spine CT examinations
    Calzado, A
    Rodríguez, R
    Muñoz, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868) : 384 - 395
  • [3] Commission of the European Communities, 1999, 16262 EUR COMM EUR C
  • [4] A practical approach to the first iteration in the optimization of radiation dose and image quality in CT: estimates of the collective dose savings achieved
    Crawley, MT
    Booth, A
    Wainwright, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (883) : 607 - 614
  • [5] The appropriate use of computed tomography
    Dixon, AK
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : S98 - S105
  • [6] Survey of conventional and spiral CT doses
    Hidajat, N
    Wolf, M
    Nunnemann, A
    Liersch, P
    Gebauer, B
    Teichgräber, U
    Schröder, RJ
    Felix, R
    [J]. RADIOLOGY, 2001, 218 (02) : 395 - 401
  • [7] International Electrotechnical Commission, 2002, 60601244 IEC INT E 2
  • [8] Jones DG, 1990, NRPBSR250
  • [9] Clinical use of image quality criteria in computed tomography: A pilot study
    Jurik, A
    Petersen, J
    Jessen, KA
    Bongartz, G
    Geleijns, J
    Golding, SJ
    Leonardi, M
    van Meerten, EV
    Panzer, W
    Shrimpton, PC
    Tosi, G
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 47 - 52
  • [10] Image quality and dose in computed tomography
    Jurik, AG
    Jessen, KA
    Hansen, J
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (01) : 77 - 81