THE EFFECT OF CATHETER TYPE AND SITE ON INFECTION-RATES IN TOTAL PARENTERAL-NUTRITION PATIENTS

被引:29
作者
KEMP, L [1 ]
BURGE, J [1 ]
CHOBAN, P [1 ]
HARDEN, J [1 ]
MIRTALLO, J [1 ]
FLANCBAUM, L [1 ]
机构
[1] OHIO STATE UNIV,DEPT SURG,NUTR SUPPORT SERV,410 W 10TH AVE,COLUMBUS,OH 43210
关键词
D O I
10.1177/014860719401800171
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Infections pose a major problem in patients receiving total parenteral nutrition. Controversy continues concerning the effect of catheter type (triple-, double-, single-lumen, or pulmonary artery), insertion site (subclavian, internal jugular, or femoral vein), and the incidence of catheter-related infections. We retrospectively studied multi-lumen catheter use for total parenteral nutrition over a 6-month period in 192 patients, a total of 3334 catheter days. Nonintensive care unit catheters were inserted by the Nutrition Support Service, and intensive care unit catheters were inserted by the intensive care unit staff. All catheters were cared for using Nutrition Support Service protocols, with multi-lumen catheters changed every 7 to 10 days and pulmonary artery catheters changed every 4 days. Infections were determined by semiquantitative cultures (> 15 colonies/plate). The incidence of infections for triple-lumen catheters was 5 (subclavian), 17 (internal jugular), and 36% (femoral) respectively; total infection rate for triple-lumen catheters was 10%. Infection rates for pulmonary artery catheters were 4 (subclavian), and 6% internal (jugular site), respectively, the overall infection rate was 5%. There were no differences in infection rates at any site based on catheter type; however, when triple-lumen catheter sites were compared, the differences were significant (p < .001 vs subclavian, chi2). Catheter duration was 7.8 days (subclavian), 7.3 days (internal jugular), and 4.6 (femoral) days. These data suggest that the use of multi-lumen catheters for total parenteral nutrition is safe, that there is a benefit associated with the subclavian route, and that the femoral site should be avoided.
引用
收藏
页码:71 / 74
页数:4
相关论文
共 21 条
[11]   PROSPECTIVE EVALUATION OF SINGLE AND TRIPLE LUMEN CATHETERS IN TOTAL PARENTERAL-NUTRITION [J].
MCCARTHY, MC ;
SHIVES, JK ;
ROBISON, RJ ;
BROADIE, TA .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1987, 11 (03) :259-262
[12]  
MONCRIEF JA, 1957, ANN SURG, V147, P166
[13]   CENTRAL VENOUS CATHETER CARE IN PARENTERAL-NUTRITION - A REVIEW [J].
MURPHY, LM ;
LIPMAN, TO .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1987, 11 (02) :190-201
[14]  
PADBERG FT, 1981, ANN SURG, V193, P264, DOI 10.1097/00000658-198103000-00002
[15]  
PEMBERTON LB, 1986, ARCH SURG-CHICAGO, V121, P591
[16]   RISK OF INFECTION ACCOMPANYING THE USE OF SINGLE-LUMEN VS DOUBLE-LUMEN SUBCLAVIAN CATHETERS - A PROSPECTIVE RANDOMIZED STUDY [J].
POWELL, C ;
FABRI, PJ ;
KUDSK, KA .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1988, 12 (02) :127-129
[17]  
Purdue G F, 1986, J Burn Care Rehabil, V7, P498, DOI 10.1097/00004630-198611000-00011
[18]  
PURDUE GF, 1991, SURG CLIN N AM, V71, P723
[19]  
ROSE ST, 1986, JPEN, V12, P511
[20]   CATHETER COMPLICATIONS IN TOTAL PARENTERAL NUTRITION - PROSPECTIVE STUDY OF 200 CONSECUTIVE PATIENTS [J].
RYAN, JA ;
ABEL, RM ;
ABBOTT, WM ;
HOPKINS, CC ;
FISCHER, JL ;
CHESNEY, TM ;
COLLEY, R ;
PHILLIPS, K .
NEW ENGLAND JOURNAL OF MEDICINE, 1974, 290 (14) :757-761