CORRELATION OF ARTERIAL AND VENOUS-BLOOD FLOW IN THE MESENTERIC SYSTEM BASED ON MR FINDINGS

被引:25
|
作者
BURKART, DJ [1 ]
JOHNSON, CD [1 ]
EHMAN, RL [1 ]
机构
[1] MAYO CLIN & MAYO FDN, DEPT DIAGNOST RADIOL, 200 1ST ST SW, ROCHESTER, MN 55905 USA
关键词
D O I
10.2214/ajr.161.6.8249742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to determine if a consistent relationship exists between (1) flow in the portal vein and superior mesenteric vein and (2) flow in the mesenteric arteries. SUBJECTS AND METHODS. Cine phase-contrast methods were used to determine volumetric flow in the celiac axis, superior mesenteric artery, portal vein, and superior mesenteric vein in 11 healthy volunteers. RESULTS. The mean (+/- SD) volumetric flow rates in the celiac axis, superior mesenteric artery, superior mesenteric vein, and portal vein were 9.9 +/- 3.2, 6.0 +/- 1.8, 5.7 +/- 2.0, and 13.7 +/- 1.8 ml/min per kilogram, respectively. A strong correlation was found between measured mesenteric arterial blood flow, defined as the sum of flow in the celiac axis and the superior mesenteric artery, and portal venous flow (r=.97, p = .00002). Good agreement was found between flow in the superior mesenteric artery and that in the superior mesenteric vein (r = .98; p = .00001; bias = 20 ml/min). CONCLUSION. There is a consistent relationship between MR measurements of flow in the portal or superior mesenteric vein and the measured flow in the arteries supplying those veins. Flow in the superior mesenteric vein is an accurate predictor of flow in the superior mesenteric artery.
引用
收藏
页码:1279 / 1282
页数:4
相关论文
共 50 条
  • [1] ARTERIAL AND VENOUS-BLOOD FLOW - NONINVASIVE QUANTITATION WITH MR IMAGING
    PELC, LR
    PELC, NJ
    RAYHILL, SC
    CASTRO, LJ
    GLOVER, GH
    HERFKENS, RJ
    MILLER, DC
    JEFFREY, RB
    RADIOLOGY, 1992, 185 (03) : 809 - 812
  • [2] MESENTERIC ARTERIAL AND VENOUS-BLOOD FLOW CHANGES FOLLOWING SELECTIVE ARTERIAL INJECTIONS OF VASODILATORS
    REDMAN, HC
    INVESTIGATIVE RADIOLOGY, 1974, 9 (03) : 193 - 198
  • [3] INTERRELATIONS BETWEEN ARTERIAL AND VENOUS-BLOOD FLOW
    ANTAL, J
    PHYSIOLOGIA BOHEMOSLOVACA, 1980, 29 (03): : 257 - 257
  • [4] DETECTING CHANGES OF ARTERIAL AND VENOUS-BLOOD FLOW IN FLAPS
    SVENSSON, H
    SVEDMAN, P
    HOLMBERG, J
    WIESLANDER, JB
    ANNALS OF PLASTIC SURGERY, 1985, 15 (01) : 35 - 40
  • [5] A MODEL OF PHASIC ARTERIAL AND VENOUS-BLOOD FLOW IN THE CORONARY CIRCULATION
    SABBAH, HN
    HAMID, MS
    RANKIN, GW
    STEIN, PD
    COMPUTERS & STRUCTURES, 1993, 46 (04) : 741 - 749
  • [6] A model of blood flow in the mesenteric arterial system
    Thusitha DS Mabotuwana
    Leo K Cheng
    Andrew J Pullan
    BioMedical Engineering OnLine, 6
  • [7] A model of blood flow in the mesenteric arterial system
    Mabotuwana, Thusitha D. S.
    Cheng, Leo K.
    Pullan, Andrew J.
    BIOMEDICAL ENGINEERING ONLINE, 2007, 6 (1)
  • [8] MESENTERIC VENOUS-BLOOD SAMPLING IN-VIVO IN RAT
    BUTTERWORTH, KR
    PELLING, D
    JOURNAL OF PHYSIOLOGY-LONDON, 1973, 232 (02): : P60 - P61
  • [9] OXYGEN STATUS OF ARTERIAL AND MIXED VENOUS-BLOOD
    SIGGAARDANDERSEN, O
    FOGHANDERSEN, N
    GOTHGEN, IH
    LARSEN, VH
    CRITICAL CARE MEDICINE, 1995, 23 (07) : 1284 - 1293
  • [10] COMPUTERIZED SYSTEM FOR THE CONTINUOUS MEASUREMENT OF AZYGOS VENOUS-BLOOD FLOW
    HAYES, PC
    TERRACE, D
    PEASTON, I
    BOUCHIER, IAD
    REDHEAD, D
    BRASH, HM
    GUT, 1992, 33 (03) : 372 - 374