EFFECT OF SURFACE-ROUGHNESS OF HYDROXYAPATITE-COATED TITANIUM ON THE BONE-IMPLANT INTERFACE SHEAR-STRENGTH

被引:85
|
作者
HAYASHI, K
INADOME, T
TSUMURA, H
NAKASHIMA, Y
SUGIOKA, Y
机构
[1] Department of Orthopaedic Surgery, Faculty of Medicine, Kyushu University, Higashi-ku, Fukuoka, 812
关键词
HYDROXYAPATITE; COATINGS; INTERFACE SHEAR STRENGTH; SURFACE ROUGHNESS; PLASMA SPRAY;
D O I
10.1016/0142-9612(94)90241-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have investigated the bone-implant interface shear strength of hydroxyapatite (HA)-coated Ti-6Al-4V (HA-coating A) (roughness average, R(a) = 3.4 +/- 0.5 mu m) and HA-coated Ti-6Al-4V with a rougher surface (HA-coating B) (R(a) = 8.4 +/- 1.8 mu m). There was no significant difference between HA-coating A and HA-coating B implants with respect to the bone-implant interface shear strength as determined in push-out tests using the transcortical model in adult dogs. The bone-implant interface shear strength of bead-coated porous Ti-6Al-4V was significantly greater than that of both HA-coating A and HA-coating B implants. The failure site, as determined by scanning electron microscopy, was the coating-substrate interface, not the coating-bone interface. This indicates a need to protect the HA coating from the direct shear forces. HA coating enhances early bone growth into the porous surface of the implant. Long-term fixation should depend on bone anchoring to this porous surface. Hydroxyapatite coatings must be developed which do not obstruct the pores of the surface of the implant.
引用
收藏
页码:1187 / 1191
页数:5
相关论文
共 49 条
  • [1] COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF SOLID HYDROXYAPATITE AND HYDROXYAPATITE-COATED TITANIUM IMPLANTS
    HAYASHI, K
    INADOME, T
    MASHIMA, T
    SUGIOKA, Y
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (05): : 557 - 563
  • [2] COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF HYDROXYAPATITE-COATED AND ALUMINA-COATED METAL IMPLANTS
    INADOME, T
    HAYASHI, K
    NAKASHIMA, Y
    TSUMURA, H
    SUGIOKA, Y
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01): : 19 - 24
  • [3] EFFECT OF SURFACE-ROUGHNESS ON ATTACHMENT STRENGTH OF BONE-IMPLANT INTERFACE
    YANAGISAWA, I
    SAIRENJI, E
    YANAGISAWA, S
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 231 - 231
  • [4] Comparison of bone-implant interface shear strength of hydroxyapatite- coated and alumina-coated metal implants
    Department of Orthopaedic Surgery, Faculty of Medicine, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812, Japan
    J. BIOMED. MATER. RES., 1 (19-24):
  • [5] TENSILE AND TORSIONAL SHEAR-STRENGTH OF THE BONE IMPLANT INTERFACE OF TITANIUM IMPLANTS IN THE RABBIT
    PROBSTER, L
    VOIGT, C
    FUHRMANN, G
    GROSS, UM
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (6-7) : 314 - 319
  • [6] Stress shielding at the bone-implant interface: Influence of surface roughness and of the bone-implant contact ratio
    Raffa, Maria Letizia
    Nguyen, Vu-Hieu
    Hernigou, Philippe
    Flouzat-Lachaniette, Charles-Henri
    Haiat, Guillaume
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (06) : 1174 - 1183
  • [7] EFFECT OF SURFACE-ROUGHNESS ON SHEAR BOND STRENGTH
    FERREIRA, MR
    RAUTENBACH, SD
    COETZEE, WJC
    JOURNAL OF DENTAL RESEARCH, 1989, 68 (04) : 727 - 727
  • [8] INTERFACE BETWEEN BONE TISSUE AND IMPLANTS OF SOLID HYDROXYAPATITE OR HYDROXYAPATITE-COATED TITANIUM IMPLANTS
    DELANGE, GL
    DONATH, K
    BIOMATERIALS, 1989, 10 (02) : 121 - 125
  • [9] Improvement of the bone-screw interface strength with hydroxyapatite-coated and titanium-coated AO/ASIF cortical screws
    Moroni, A
    Faldini, C
    Rocca, M
    Stea, S
    Giannini, S
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (04) : 257 - 263
  • [10] EFFECT OF SURFACE-ROUGHNESS ON SHEAR BOND STRENGTH TO DENTIN
    WINKLER, MM
    MOORE, BK
    RHODES, B
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 132 - 132