Diabetes Insulin Guidance System: a real-world evaluation of new technology (d-Nav) to achieve glycaemic control in insulin-treated type 2 diabetes

被引:10
作者
Donnelly, R. [1 ]
Carr, S. [1 ]
Harper, R. [1 ]
机构
[1] Ulster Hosp, Dept Endocrinol Diabet, Belfast, Antrim, North Ireland
关键词
d-Nav; insulin guidance; assistive technology; type; 2; diabetes;
D O I
10.1002/pdi.1966
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim was to conduct a service evaluation of the effectiveness of using d-Nav (a handheld device that automates the process of insulin dosage titration using the Diabetes Insulin Guidance System [DIGS] software) in achieving glycaemic control in patients with type 2 diabetes. The study comprised an exploratory single-centre pilot evaluation of the use of d-Nav in patients with type 2 diabetes aged >= 21 years with an HbA1c level >= 53mmol/mol (>= 7.0%) who were receiving insulin therapy for at least one year. Patients were asked to use d-Nav to monitor their blood glucose level before every insulin injection and, when they suspected the occurrence of hypoglycaemia, to allow d-Nav to adjust their insulin dosage. At scheduled three-monthly clinic visits, HbA1c was measured and information on episodes of hypoglycaemia collected from d-Nav and by patient reporting. Patients were followed for a minimum of six months. A total of 94 patients completed the evaluation as active users. The mean (+/- standard deviation) HbA1c for active users decreased from 77 +/- 15mmol/mol (9.2 +/- 1.4%) at baseline to 62 +/- 13mmol/mol (7.8 +/- 1.2%) at the three- to five-month clinic visit and to 59 +/- 13mmol/mol (7.5 +/- 1.2%) at the six-to 12-month clinic visit. In patients for whom paired data were available, the decreases were statistically significant at both post-baseline visits (both p<0.001). The frequency of minor hypoglycaemia (blood glucose <= 3.6mmol/L) was low and well within the tolerated range. In conclusion, d-Nav is shown to be a safe and effective solution for blood glucose management in insulin users with type 2 diabetes. Copyright (C) 2015 John Wiley & Sons.
引用
收藏
页码:247 / 253
页数:7
相关论文
共 23 条
[1]   Adjust to target in type 2 diabetes - Comparison of a simple algorithm with carbohydrate counting for adjustment of mealtime insulin glulisine [J].
Bergenstal, Richard M. ;
Johnson, Mary ;
Powers, Margaret A. ;
Wynne, Alan ;
Vlajnic, Aleksandra ;
Hollander, Priscilla ;
Rendell, Marc .
DIABETES CARE, 2008, 31 (07) :1305-1310
[2]  
Bergenstal RM, 2012, DIABETES TECHNOL THE, V14, P1
[3]   Glucose Meters with Built-In Automated Bolus Calculator: Gadget or Real Value for Insulin-Treated Diabetic Patients? [J].
Colin, Ides M. ;
Paris, Isabelle .
DIABETES THERAPY, 2013, 4 (01) :1-11
[4]   Hypoglycaemia: The limiting factor in the glycaemic management of Type I and Type II Diabetes [J].
Cryer, PE .
DIABETOLOGIA, 2002, 45 (07) :937-948
[5]   The Barrier of Hypoglycemia in Diabetes [J].
Cryer, Philip E. .
DIABETES, 2008, 57 (12) :3169-3176
[6]   How Our Current Medical Care System Fails People With Diabetes Lack of timely, appropriate clinical decisions [J].
Davidson, Mayer B. .
DIABETES CARE, 2009, 32 (02) :370-372
[7]  
Diabetes UK, 2007, INS PILL REPL INJ
[8]  
Diabetes UK, 2012, STAT NAT 2012 ENG
[9]  
Diabetes UK and NHS Diabetes, 2011, 2010 DIAB SPEC NURS
[10]   Frequency and predictors of hypoglycaemia in Type 1 and insulin-treated Type 2 diabetes: A population-based study [J].
Donnelly, LA ;
Morris, AD ;
Frier, BM ;
Ellis, JD ;
Donnan, PT ;
Durrant, R ;
Band, MM ;
Reekie, G ;
Leese, GP .
DIABETIC MEDICINE, 2005, 22 (06) :749-755